38
8 - INSTALLATION - Vent & combustion air
Vent pipe materials and fi ttings must comply with the following standards
Item
Material
Standard for
installation in USA
Standard for
installation in Canada
Vent pipe and
fi ttings
PVC Schedule 40, 80
ANSI/ASTM D1785
ULC-S636
CPVC schedule 40/80
ANSI/ASTM F441
Polypropylene
ULC-S636
Stainless steel AL29-4C
UL1738
Pipe cement/primer
PVC
ANSI/ASTM D2564
CPVC
ANSI/ASTM F493
Approved vent manufacturers and items
Item
Materials
Manufacturer/supplier
Manufacturer/supplier part number
Concentric roof or wall terminal
PVC
IPEX (System 636)
196006
Two pipes wall terminal
PVC
IPEX (System 636)
081219 or 196985
Single pipe wall terminal (90°elbow)
PVC
IPEX (System 636)
196025
Boiler adapter (80mm to 3” PVC)
Polypropylene
COSMOGAS
62617303
Bird Screen
PVC
IPEX (System 636)
196051
Two pipes roof terminal
Polypropylene
COSMOGAS
62617306 and 61302003
Two pipe wall terminal
Polypropylene
COSMOGAS
61302004 and 61302003
Single pipe roof terminal
Polypropylene
COSMOGAS
62617306
Single pipe wall terminal
Polypropylene
COSMOGAS
61302004
Two or single pipe boiler adapter (80mm to
80mm Polypropylene)
Polypropylene
COSMOGAS
62617286
Bird Screen
Polypropylene
COSMOGAS
61302003
Concentric boiler adapter
Polypropylene
COSMOGAS
62617224
Concentric roof terminal
Polypropylene
COSMOGAS
62617304
Concentric wall terminal
Polypropylene
COSMOGAS
62617232
Single pipe wall or roof terminal
Polypropylene
Centrotherm (Innofl ue System)
IESP0339
Two pipes wall or roof terminal
Polypropylene
Centrotherm (Innofl ue System)
ASEP0339 and ISEL0387UV
Bird screen
Polypropylene
Centrotherm (Innofl ue System)
IASPP03
Single pipe wall or roof terminal
Polypropylene
Duravent ( PolyPro)
3PPS36B
Two pipes wall or roof terminal
Polypropylene
Duravent ( PolyPro)
3PPS36B and 3PPS-E90B
Bird Screen
Polypropylene
Duravent ( PolyPro)
3PPS-BG
Single pipe wall or roof terminal
Stainless Steel
Duravent (FasNSeal)
FSVL3603
Two pipes wall or roof terminal
Stainless Steel
Duravent (FasNSeal)
FSVL3603 and FSELB8803
Boiler adapter (80mm to 3” stainless steel)
Stainless Steel
Duravent (FasNSeal)
FSA-80MM3
Bird Screen
Stainless Steel
Duravent (FasNSeal)
FSBS3
Single pipe wall or roof terminal
Stainless Steel
Heat Fab ( SGV)
SGV03L36
Two pipes wall or roof terminal
Stainless Steel
Heat Fab ( SGV)
SGV03L36 and FSEL8803
Boiler adapter (80mm to 3” stainless Steel) Stainless Steel
Heat Fab ( SGV)
SGV03AD80
Bird screen
Stainless Steel
Heat Fab ( SGV)
SGV03TM
WARNING!!! USE OF CELLULAR CORE PVC, CPVC AND RADEL FOR VENTING SYSTEM IS NOT ALLOWED.
TABLE 4
TABLE 5
APPROVED VENT MANUFACTURERS AND ITEMS
Содержание Peerless Combi 160
Страница 3: ...3 SAFETY INSTRUCTIONS...
Страница 97: ...97 13 MAINTENANCE...
Страница 105: ...105 NOTES...
Страница 106: ...106 NOTES...