1 - INSTALLATION - CODE REQUIREMENTS
1.1 - National
installation
legislation
- The installation must conform to the
requirements of the authority having
jurisdiction or, in the absence of such
requirements, to the latest edition of
the
National Fuel Gas Code, ANSI
Z223.1/NFPA 54
and or
CAN/CSA
B149.1, Natural Gas and Propane
Installation Code.
- Where required by the authority
having jurisdiction, the installation
must conform to the Standard for
Controls and Safety Devices for
Automatically Fired Boilers, ANSI/
ASME CSD-1.
NOTICE!
This boiler meets the safety and
other performance requirements as
specifi ed in ANSI Z21.13 standard
- Per DOE mandate, the operator
control incorporates an automatic
means (outdoor reset) of adjusting
the boiler hot water temperature for
hot water heating. The boiler must not
operate without the automatic means
enabled.
IMPORTANT!
In accordance with Section 325 (f)(3)
of the energy policy and conservation
Act, this boiler is equipped with a
feature that saves energy by reducing
the boiler water temperature as the
heating load decreases. This feature
is equipped with an override which is
provided primarily to permit the use
of an external management system
that serves the same function. THIS
OVERRIDE MUST NOT BE USED
UNLESS AT LEAST ONE OF THE
FOLLOWING CONDITIONS IS
TRUE:
An external energy management
system is installed that reduces
the boiler water temperature as the
heating load decreases.
This boiler is not used for any
space heating.
This boiler is part of a modular
multiple boiler system having a total
input of 300,000 BTU/hr or greater.
This boiler is equipped with a
tankless coil.
1.2- Commonwealth
of Massachusetts
Installation
Requirements
In the Commonwealth of
Massachusetts, the installation
must be performed by a licensed
plumber or gas fi tter.
WARNING!!!
WARNING!!!
Improper
venting can result in excessive
levels of carbon monoxide
which can cause severe
personal injury or death!
(a) For all side wall horizontally
vented gas fueled equipment
installed in every dwelling, building
or structure used in whole or in
part for residential purposes,
including those owned or operated
by the commonwealth and
where the side wall exhaust vent
termination is less than seven (7)
feet above fi nished grade, in the
area of the venting, including but
not limited to decks and porches,
the following requirements shall be
satisfi ed:
1. INSTALLATION OF CARBON
MONOXIDE DETECTORS. At
the time of installation of the side
wall horizontal vented gas fueled
equipment, the installing plumber
or gasfi tter shall observe that
a hard wired carbon monoxide
detector with an alarm and battery
back-up is installed on the fl oor
level where the gas equipment
is to be installed. In addition, the
installing plumber or gasfi tter shall
observe that a battery operated
or hard wired carbon monoxide
detector with an alarm is installed
on each additional level of the
dwelling, building or structure
served by the side wall horizontal
vented gas fueled equip-ment.
It shall be the responsibility of
the property owner to secure the
services of qualifi ed licensed
professionals for the installation
of hard wired carbon monoxide
detectors.
a. In the event that the side wall
horizontally vented gas fueled
equipment is installed in a crawl
space or an attic, the hard wired
carbon monoxide detector with
alarm and battery back-up may
be installed on the next adjacent
fl oor level.
b. In the event that the
requirements of this subdivision
can not be met at the time
of completion of installation,
the owner shall have a period
of thirty (30) days to comply
with the above requirements;
provided, however, that during
said thirty (30) day period,
a battery operated carbon
monoxide detector with an
alarm shall be installed.
2. APPROVED
CARBON
MONOXIDE DETECTORS. Each
carbon monoxide detector as
required in accordance with the
above provisions shall comply with
NFPA 720 and be ANSI/UL 2034
listed and IAS certifi ed.
3. SIGNAGE. A metal or plastic
identifi cation plate shall be
permanently mounted to the
exterior of the building at a
minimum height of eight (8) feet
above grade directly in line with
the exhaust vent terminal for the
horizontally vented gas fueled
heating appliance or equipment.
The sign shall read, in print size
no less than one-half (1/2) inch
in size,
“GAS VENT DIRECTLY
BELOW. KEEP CLEAR OF ALL
OBSTRUCTIONS”.
4. INSPECTION. The state or local
gas inspector of the side wall
horizontally vented gas fueled
equipment shall not approve
the installation unless, upon
inspection, the inspector observes
carbon monoxide detectors and
signage installed in accordance
with the provisions of 248 CMR
5.08(2)(a)1 through 4.