4 • Alarms
Model 3120 RAS Administrators’ Reference Guide
28
Displaying the Alarms window
•
Modify Alarms—Clicking on this link takes you to a window where you can change how the access server
perceives the severity of each alarm (“Modify Alarms—Configuring alarm severity levels” on page 30)
Alarm Response Outputs
Alarm Response Outputs display the current settings for handling alarm notification via SYSLOG/SNMP
messages. To change how the SYSLOG/SNMP function notifies remote users of an alarm, refer to “Modify
Response—Configuring the alarm response system” on page 29.
Alarm Syslog Priority (syslogAlarmPriority)
Displays the SYSLOG priority of the alarm SYSLOG message. If the minimum priority for SYSLOG daemon
(set under the System Log link) is less than this value, the SYSLOG daemon will receive the major or critical
alarm SYSLOG message.
Alarm SNMP Trap IP 1 (alarmTrapIp0)
The IP address of a host system which is running the SNMP trap daemon. Critical and major alarm messages
will be sent to the system. If set to 0.0.0.0 then no trap message will be sent in response to a major alarm.
Alarm SNMP Trap IP 2 (alarmTrapIp1)
The IP address of a host system which is running the SNMP trap daemon. Critical and major alarm messages
will be sent to the system. If set to 0.0.0.0 then no trap message will be sent in response to a major alarm.
Alarm SNMP Trap IP 3 (alarmTrapIp2)
The IP address of a host system which is running the SNMP trap daemon. Critical and major alarm messages
will be sent to the system. If set to 0.0.0.0 then no trap message will be sent in response to a major alarm.
Alarm SNMP Trap IP 4 (alarmTrapIp3)
The IP address of a host system which is running the SNMP trap daemon. Critical and major alarm messages
will be sent to the system. If set to 0.0.0.0 then no trap message will be sent in response to a major alarm.
Temperature Threshold (boxAlarmTemperature)
If the box registers a temperature greater than this temperature an alarm will be reported. Temperature is
reported in degrees Celsius.
Current Box Temperature (boxTemperature)
Displays the current temperature in Celsius.
Clear All Alarms
Clicking on this button resets all alarms to a non-alarm condition. Clear All Alarms does the following for all
alarms: it resets the alarm, resets Alarm Time to 0.0 seconds, and resets the Alarm Count to 0.
Alarms
This portion of the Alarms main window displays the alarm status table, where you can view current alarm sta-
tus, manually generate an alarm as a test, and clear the alarm time and alarm count variables.
Alarm ID (alarmDefIndex)
This number identifies the alarm item.
Alarm Name (alarmName)
The alarm items are grouped into two categories: Box and WAN trunk alarms. The Box group category lists
access server temperature and power supply status. The WAN category monitors the T1/E1/PRI ports for yel-
low and red alarms.
Содержание 3120
Страница 8: ...Contents Model 3120 RAS Administrators Reference Guide 8...
Страница 12: ...About this guide Model 3120 RAS Administrators Reference Guide 12...
Страница 16: ...1 Introduction Model 3120 RAS Administrators Reference Guide 16 Saving HTTP HTML Object Changes...
Страница 21: ...21 Chapter 3 Import Export Chapter contents Introduction 22 Export Configuration 22 Import Configuration 24...
Страница 32: ...4 Alarms Model 3120 RAS Administrators Reference Guide 32 Modify Alarms Configuring alarm severity levels...
Страница 134: ...8 Dial Out Model 3120 RAS Administrators Reference Guide 134 An example section of dialout...
Страница 140: ...9 Callback Access Server Administrators Reference Guide 140 Dialout...
Страница 176: ...13 Filter IP Model 3120 RAS Administrators Reference Guide 176 An example of using a filter...
Страница 178: ...14 Frame Relay Model 3120 RAS Administrators Reference Guide 178 Congestion frameEnableCongestion 184...
Страница 226: ...17 MFR Version 2 Model 3120 RAS Administrators Reference Guide 226 MFR Version 2 Modify...
Страница 238: ...19 SNMP Model 3120 RAS Administrators Reference Guide 238 Out...
Страница 250: ...20 System Model 3120 RAS Administrators Reference Guide 250 System Packet Holding Message Blocks...
Страница 299: ...299 Chapter 24 About Chapter contents Introduction 300 Patton Electronics Company contact information 300...
Страница 304: ...25 License Model 3120 RAS Administrators Reference Guide 304 End User License Agreement...
Страница 309: ...309 Appendix B MIB trees Chapter contents Model 2960 MIB Tree Structure 310...