Operating Status Variables
19
Model 3120 RAS Administrators’ Reference Guide
2 • Home
Operating Status Variables
There are seven system variables which describe the immediate operating status access server. These variables
are shown in figure 4 and are described in the following sections.
Figure 4. STATUS menu
Active Calls (diActive)
This number, ranging from 0 to 120 displays the total number of calls being processed (connecting, online,
authenticating, and so on) in the access server at the time the HOME page was displayed.
Peak Active Calls (diMaxActive)
The maximum number of active calls seen at one time since the access server was powered on.
Total Calls (diTotalCallAttempts)
The total number of calls attempted since the last boot of the box.
DSPs Not Working (dspFailed)
This number should always be zero. The DSPs in the access server are arranged as a resource pool and called
upon at ring-time. If a DSP fails to respond to the access server’s CPU, it is determined to have failed, at which
point the CPU will remove the DSP from the resource pool. If an incoming call attempts to access the failed
DSP, the RAS will answer, then terminate the call (to a person monitoring the failed call through a telephone
handset, he or she will hear only silence during the call, ending with a faint click as the call is terminated). One
symptom indicating that a DSP has failed is if the access server is not handling as many calls as it normally does.
Total DRAM Detected (boxDetectedMemory)
This number shows the total number of bits of installed and available DRAM.
Running Since Last Boot (sysUpTime)
This tells you how long the access server has been running since the it was last reset. It displays the number of
hours and rolls over after 1,193 hours (497 days).
Содержание 3120
Страница 8: ...Contents Model 3120 RAS Administrators Reference Guide 8...
Страница 12: ...About this guide Model 3120 RAS Administrators Reference Guide 12...
Страница 16: ...1 Introduction Model 3120 RAS Administrators Reference Guide 16 Saving HTTP HTML Object Changes...
Страница 21: ...21 Chapter 3 Import Export Chapter contents Introduction 22 Export Configuration 22 Import Configuration 24...
Страница 32: ...4 Alarms Model 3120 RAS Administrators Reference Guide 32 Modify Alarms Configuring alarm severity levels...
Страница 134: ...8 Dial Out Model 3120 RAS Administrators Reference Guide 134 An example section of dialout...
Страница 140: ...9 Callback Access Server Administrators Reference Guide 140 Dialout...
Страница 176: ...13 Filter IP Model 3120 RAS Administrators Reference Guide 176 An example of using a filter...
Страница 178: ...14 Frame Relay Model 3120 RAS Administrators Reference Guide 178 Congestion frameEnableCongestion 184...
Страница 226: ...17 MFR Version 2 Model 3120 RAS Administrators Reference Guide 226 MFR Version 2 Modify...
Страница 238: ...19 SNMP Model 3120 RAS Administrators Reference Guide 238 Out...
Страница 250: ...20 System Model 3120 RAS Administrators Reference Guide 250 System Packet Holding Message Blocks...
Страница 299: ...299 Chapter 24 About Chapter contents Introduction 300 Patton Electronics Company contact information 300...
Страница 304: ...25 License Model 3120 RAS Administrators Reference Guide 304 End User License Agreement...
Страница 309: ...309 Appendix B MIB trees Chapter contents Model 2960 MIB Tree Structure 310...