24
PA8500-VES System
System Manual | 2014
UK
CR8506-V
|
RT8506-V
• PMD amplifiers
IMPORTANT NOTICE!
All the amplifiers connected to a line must necessarily have progressive addresses, from number 1 onwards (max 16 for each line). To
set the address of each single amplifier, consult the “Settings” section in the instruction booklet of the PMD range (PASO code number
11/733).
Supposing.you.wish.to.set.line
2
.for.connection.to.amplifiers.of.the.PMD.range:.after.pressing.
LINE 2 > Configure
and.selecting.
PMD - amplifiers
the.
Line 2 configuration
window.will.open..
In.this.window.it.is.possible.to.list.the.amplifiers.(and.their.models).connected.to.the.lines.in.question,.in.addition.to.indicating.whether.they.are.
stand-by.amplifiers..The.associations.between.the.various.different.amplifiers.and.the.standby.units.as.selected.under.the.heading.“Configuring.
the.standby.amplifiers”.(Page..27).are.also.highlighted..The.programme.will.guide.you.through.the.procedure.in.order.to.ensure.that.several.rules.
are.followed:
-. The.entries.are.sequential,.starting.from.address.1..If.an.amplifier.half-way.down.the.list.is.deleted.by.selecting.
model = “none”
as.the.model,.
therefore,.all.the.amplifiers.with.the.next.addresses.will.also.be.removed.
-. One.line.can.manage.up.to.a.maximum.of.two.standby.units..The.first.of.these.is.“global”,.that.is.to.say.it.can.replace.the.amplifiers.of.any.other.
line.of.the.controller..The.second.standby.unit.can.be.either:
.
•.“global”.if.there.are.only.two.standby.units.on.the.lines;.or
.
•.“local”.if.there.are.additional.amplifiers.on.the.line..In.this.case,.the.standby.unit.can.only.replace.amplifiers.belonging.to.the.same.line.as.
the.unit.itself.
The.programme.carries.out.cross-checks.to.ensure.that.the.compilation.is.correct.
Once.you.have.completed.the.compilation,.press.
End
.to.save.the.configuration,.which.will.appear.associated.with.line.2.in.the.main.window..As.
an.alternative,.you.may.press.
Cancel
.to.exit.without.saving.the.changes.made..
• PA8506-V compact system
For. line.
3
,. set. a. connection. to. a. PA8506-V. compact. system:. after. pressing..
LINE 3 > Configure
and. selecting. the. item.
PA8506-V - compact
the.
Line 3
configuration
window.will.open.
Once.you.have.set.the.parameters.for.all.the.lines,.go.on.to.compile.the.other.
four. connections. shown. in. the. main. window:. CTR. INPUT,. CTR. OUTPUT,.
EMERGENCY.UNITS.and.BROADCASTING.UNITS.