43
System Manual | 2014
PA8500-VES System
UK
CR8506-V
|
RT8506-V
Label
Part being diagnosed
Display
Cause
Action required
All
All
Ok
No.failure
-
N.T.
Diagnostics.disabled.during.
configuration.(see.Set>.
BACkGROUND.TEST.menu).
-
Res.
Failure.(Fault.signal).cleared
Access.the.Report>.FAULTS.panel.from.the.
OPERATOR.menu.and.carry.out.a.MANUAL.
RESET.of.the.FAILURE.signal.
1-Local.emerg.
Hand-held.microphone.or..
Emergency.Push-button.
Fault
Failure.of.hand-held.microphone.
or.of.Emergency.Push-button.
Make sure that the microphone has been
correctly plugged into the socket on the front
panel. If the failure persists, contact the Service
Centre.
2-Configuration
SD.card
Fault
SD.card.error.or.error.in.reading.
messages.
Make.sure.that.the.SD.card.has.been.correctly.
plugged.into.its.slot.on.the.rear.panel.of.the.
controller.
3-Emerg..Unit
Emergency.
microphone.stations
Fault
Failure.of.at.least.one.
emergency.microphone.station.
Make.sure.that.the.microphone.of.the.station.
is.correctly.plugged.in..
If the failure persists,
contact the Service Centre.
4-Messages
Recorder/player.of.the.
emergency.EVAC.and.ALERT.
message
Fault
Presence.of.two.or.more.failures.
Make.sure.that.the.SD.card.has.been.correctly.
plugged.into.its.slot.on.the.rear.panel.of.the.
controller.
5-Line.connect.
CAT5.connection.to:.
-.PMD.
-.RT.
-.AMP
Fault
Communication.error.
Check.the.connections..
If the failure persists,
contact the Service Centre.
6-Remote.Link
Intercommunication.with.
remote.CR8506-V.units
Fault
Press.key.
6
.to.access.the.dedicated.“LINk.
FAULTS”.panel..Check.the.connecting.cables.
between.the.CR8506-V.units.for.connection.
CR8506-V.LINk..
If the failure persists, contact the Service
Centre.
Tab..8.4.1.3