18
PA8500-VES System
System Manual | 2014
UK
CR8506-V
|
RT8506-V
R4.
.
PAGING UNITS
.
Input.for.connecting.paging.microphone.stations.(PMB106-G,.PMB112-G).for.broadcasting.functions..It.is.possible.to.connect.up.to.a.total.of.16.
Paging.Units..RJ45.sockets.(2.off).for.connection.with.Cat..5e.SF/UTP.cable.with.shielding.braiding.and.shielded.STP.connector..The.connection.
with.the.Paging.Units.must.be.of.the.daisy-chain.type..The.two.connecting.lines.can.reach.a.total.length.between.them.of.up.to.1.km.
R5.
.
IN. 2 – MIC. / LINE and PRECEDENCE TERMINAL STRIP
.
INPUT.2.is.a.balanced.input.for.a.microphone.or.an.external.source,.programmable.as.a.Music.or.Voice.source..Use.the.MIC.input.to.connect.
dynamic.or.electret.microphones,.enabling.the.phantom.power.supply.or,.as.an.alternative,.the.input.on.the.terminal.strip.for.sources.at.line.
level.such.as.mixers.or.pre-amplified.microphone.stations..The.input.can.be.set.in.many.different.ways,.depending.on.how.the.operating.
mode.is.programmed:..
.
-. as.a.Voice.source.enabled.by.the.precedence.contact.(PREC.),.with.a.CHIME.that.can.be.activated/de-activated..
.
-. as.a.voice.source.for.automatic.VOX.activation.with.adjustment.of.the.activation.threshold.and.of.the.release.time.and.the.possibility.of..
. an.activatable/de-activatable.CHIME.
.
When.used.as.a.voice.source,.the.priority.can.be.set.with.7.different.levels,.and.the.group.of.paging.zones.can.be.selected..
.
Do.not.use.simultaneously.the.MIC..and.LINE.inputs.of.the.IN..2.input.but:
.
-...the.XLR.F.socket.for.connecting.a.balanced.signal.of.up.to.100.mV,.or
.
-...the.socket.with.3.terminals,.HOT-COM-GND,.for.stripped.wire,.for.connection.of.a.balanced.signal.of.up.to.1.8.V.
.
In.both.cases,.use.shielded.balanced.microphone.cable..For.details.concerning.the.settings.of.the.IN..2.input,.refer.to.the.information.
shown.in.the.Music.menu.and.under.AUDIO.SETTINGS.>.INPUT.2.and.CHIME..
PRECEDENCE TERMINAL STRIP
Terminal.strip.for.connecting.the.precedence.contact.to.the.current.music.source,.for.activation.of.the.IN..1.or.IN..2.inputs.and.of.the.CHIME,.if.
enabled..The.precedence.function.can.be.used.in.either.of.the.3.following.ways
..
The.precedence.function.can.be.used.with.MIC.1.or.MIC.2.if.
it.is.enabled.on.their.control.panels..For.details.of.the.precedence.settings,.refer.to.the.indications.shown.on.the.INPUT.1.and.INPUT.2.panels.
and.in.the.AUDIO.SETTING.menu..Activation.is.carried.out.keeping.the.+12.V.terminal.connected.to.the.PR..terminal,.by.closing.a.dry.contact.
or.connecting.the.available.precedence.contact.to.PASO.table-top.microphones.of.the.B701,.B711.or.B53.ranges.
R6.
.
IN. 1 – MIC 1
.
INPUT.1.input.for.an.external.microphone,.programmable.as.a.Music.or.Voice.source..It.is.possible.to.connect.dynamic.or.electret.
microphones.to.this.input,.enabling.the.phantom.power.supply..Programming.of.the.operating.mode.enables.use.as.a.voice.source.
enabled.by.a.precedence.contact.(PREC.),.with.the.possibility.of.activating/de-activating.a.CHIME..
.
When.it.is.used.as.a.Voice.source,.it.is.possible.to.set.priority,.to.7.different.levels,.and.the.group.of.paging.zones..The.XLR.-F.socket.
enables.a.balanced.signal.of.up.to.100.mV.to.be.connected,.by.means.of.shielded.balanced.microphone.cable..For.details.concerning.
the.settings.of.the.IN..1.input,.refer.to.the.indications.contained.in.the.INPUT.1.panel.(point.8.3.4).
R7.
.
LINE AUx IN
.
Input.for.connecting.an.external.source.of.music..It.has.one.pair.of.RCA.sockets,.with.conversion.to.mono,.for.sources.with.unbalanced.
outputs.at.line.level..For.the.audio.settings.of.the.AUX.input,.refer.to.the.information.contained.in.the.MUSIC.menu.
R8.
.
CONTROL INPUTS
.
7
.digital.inputs.for.monitoring.via.external.peripheral.units..They.enable.programmed.events.to.be.activated,.including.switching.of.the.
CR8506-V.system.to.a.Voice.Emergency.condition,.requiring.automatic.sending.of.pre-recorded.emergency.messages..Activation.is.
possible.by.means.of.Normally.Open.or.Normally.Closed.contacts,.relaying.the.+24.VDC.voltage.supplied.from.the.service.sockets..It.
is.possible.to.enable.diagnostics.of.the.connecting.stretch,.arranging.to.install.two.10-kOhm.balancing.resistors.in.the.proximity.of.the.
contact.for.activating.the.remote.peripheral.unit..(see.page.14).
R9.
.
SLAVE LINK OUTPUTS
.
6.output.lines.for.connection.to.PMD.amplifiers.and/or.PA8506-V.compact.emergency.systems.and/or.RT8506-V.routers..
R10.
.
LAN
.
Socket.for.connecting.an.Ethernet.10/100.Local.Area.Network.using.the.TCP/IP.protocol..
R11.
.
RELAY 1 – RELAY 2 – RELAY 3
.
3
.relay.outputs.for.signalling.to.external.peripheral.units..The.CR8506-V.system.enables.the.logical.outputs.to.be.programmed.to.link.
activation.of.the.output.with.system.status.events.or.for.override.functions.in.connection.with.emergency.conditions,.or.for.signalling.
failures,.emergencies.and.disabling..All.the.outputs.can.be.programmed.to.be.either.Normally.Active.or.Normally.De-activated...The.
connection. calls. for. 3. screw-down. terminals. for. stripped. wires. for. each. relay,. referred. to. N.O.. and. N.C.. contacts. -. Changeover..
N.B.: Two outputs are available on the RT8506-V router.
R12.
.
Terminals for external 24 VDC power supply
.
Terminals.for.connecting.the.auxiliary.24.VDC.power.supply..This.is.not.used.when.the.230.VAC.mains.power.supply.is.available...The.
input.is.protected.against.inversion.of.the.poles..Consult.the.“Power.supply.and.earthing”.and.“Safety.Notes”.sections.for.details.about.
safety...
N.B.: The batteries and the battery-charger must be installed on the same rack on which the CR8506-V controller is
mounted.
R13.
.
Frame connection
.
The.frame.connection.may.be.used.to.connect.other.equipment.only.for.the.purpose.of.shielding.the.low.signals..This.terminal.may.not.
be.used.to.connect.the.frame.to.earth.for.safety.purposes..(Consult.the.“Power.supply.and.earthing”.and.“Safety.Notes”.sections.for.
details.about.safety).
R14.
.
Plug for 230 VAC mains power with built-in fuse
.
Plug.for.connecting.the.equipment.to.the.230.VAC/50-60Hz.mains.power.using.the.power.cable.supplied.with.it..If.it.is.necessary.to.
replace.the.mains.fuse,.this.must.be.done.with.one.of.the.same.type,.i.e..500.mA.fuse,.of.the.miniature.20.mm.cylindrical.type..(consult.
the.“Power.supply.and.earthing”.and.“Safety.Notes”.sections.on.page.8.for.details.about.safety).