Inappropriate handling and use could cause
serious accidents. Never stack the cylinders or
expose to excessive heat, flames or sparks. Do
not bash the cylinders together. Contact your
supplier for further information on the use and
maintenance of the cylinders.
Warning: Never use damaged cylinders: in this
case, advise your supplier immediately.
20. ORDINARY MACHINE MAINTENANCE
Every three months periodically remove dust from
the suction nozzle using compressed air. Always
direct the air from the inside towards the outside
of the machine to avoid blowing dirt inside the
welder. When carrying out this operation, always
make sure the machine is not connected to the
power supply.
22. MEMORISING THE WORK POINT As
illustrated in the previous paragraphs, the
welder allows for a notable personalisation of
the work point (when used both manually and
synergically). The work point for a workpiece
can be saved in the memory and rapidly recalled
at a later date. To save a work point follow the
instructions below:
1. Select ready to weld on the display.
2. Set the appropriate parameters for the welding
mode required.
5- Press switch 10 to confirm the selected letter.
6- Repeat steps 2 and 3 to complete the name.
7- Confirm the name by pressing the TICK button
again . From this moment onwards the work
point will be memorised with its own name and
displayed with the other welding procedures.
Meaning of the back :
sp button: cancels the previous letter
inserted.
Cancel: cancels the operation.
OK: confirms the name of the work point
. 23. LOCKING A WORK POINT
The welder can lock the functions of switch
9 and 10, so that once a work point has been
saved it cannot be changed, unless modified by
a member of staff with a password, which can be
defined at the discretion of the user. To proceed
with locking a work point, it is necessary to first
enter the necessary parameters for the required
welding settings. Once this has been done,
proceed as follows:
1. Press switch 9 of fig. 1 for approximately 5
seconds; the message in Fig. A will appear.
3- Press the MEM+ button (4 of fig 1).
4- Turn switch 10 (fig 1), chose the first letter of
the name with which you want to save the work
point.