Once the type of wire has been selected (using
switch 10), the settings page for the welding wire
diameter will appear.
L2 span: When the two level mode is active the
duration of the second power level can be set.
L2 amplitude: When the two level mode is active
the second power level (L2) can be set with
respect to the set power (level L1).
2t-4t-4bilevel: This function adjusts the 2 step or
4 step settings.
2t: In 2 step mode, the machine will weld for as
long as the torch trigger is pressed down.
4t: : In 4 step mode, press the trigger once to
start the torch, press again to stop the torch.
4Bi: In 4 step Bi- Level mode, press the trigger
once to start the torch, successively, briefly
pressing the trigger (for less than 1s) will cause
the set welding current to pass to second level
and vice versa. Prolonged pressure on the torch
trigger will halt the welding process.
2nd level: This option is for setting the values the
wire speed, corresponding to the second power
level, which is active when the values of the
2t-4t-4bi-level is set to 4bi.
Initial/final current: it allows to switch up (ON) or
down (OFF) mode with starting/final current.
Initial current: allows setting the value at which
the welding current is brought to immediately
after the striking of the electric arc
Initial time: allows setting the time of the current
established by the Initial Current parameter. In
4t/4bi mode this time is irrelevant and the initial
current is kept for as long as the torch button is
held down.
Ramp ls- > l1: allows setting the duration of the
upslope of the welding current.
Ramp l1- > lf: allows setting the duration of the
downslope of the welding current
Final current: allows setting the value at which
the welding current is brought to on completion
of the downslope
Final time: allows setting the time of the current
established by the Final Current parameter. In
4t/4bi mode, this time is irrelevant and the final
current is kept for as long as the torch button is
held down.
Spot welding: This sets the maximum welding
duration (when different to 0), in seconds.
Pause: This sets the duration of the pauses
(when different to 0), between two successive
tacks.
Pre gas time: This sets the gas supply time
before the welding current is supplied.
Post gas time: This sets the gas supply time after
the welding current supply ends. 13
Burnback: This adjusts the length of the wire in
Selecting this option will take you to the welding
screen:
Arc length: This changes the length of the electric
weld arc with respect to the pre-set synergic
values.
Deposit: This modifies the deposit of the filler
material (velocity of the wire) with respect to the
pre-set synergic values. I
nductance: This changes the variation speed of
the welding current to achieve a sharper (low
values) or softer arc (high values).
Double short: This activates (ON) or deactivates
(OFF) the two level option, i.e. the continuous
switching between two different welding tension
levels.
L1 span: When the two level mode is active the
duration of the first power level can be set.
Содержание DP231C
Страница 1: ...ISSUE 2 User Manual DP231C...
Страница 2: ......
Страница 3: ......
Страница 4: ......