Chapter 3: Connecting to a Computer
Setting Up the Monitor
PHM/PM User Guide
3-5
The drivers are also located on the OS image in the following directory:
C:\TSHARC for the Hampshire driver
C:\UPDD for the UPDD driver
Review the Install Readme.txt file associated with the touchscreen driver
for more information on installing it, if necessary.
Step 2: Calibrating the Touchscreen
Calibrating the touchscreen ensures that it is aligned with your display. The
monitor’s touchscreen is calibrated before leaving Parker. However, you
may need to recalibrate the touchscreen when you begin using the monitor
for the first time or whenever the cursor does not follow the touches on the
screen.
Calibration using the Hampshire Driver - PHM Monitors
This section explains how to calibrate the Hampshire touchscreen driver
under Windows 2000 and XP Professional.
1
Select Start Programs Hampshire TSHARC Control Panel. The
control panel appears.
2
Follow the on screen instructions for selecting which monitor to
calibrate. If you just have one monitor, select 1.
3
Select the Calibrate tab.
4
Click the center of where the arrows are pointing. The Calibration
screen appears.
5
Touch the target where it appears on the screen, hold your finger
there momentarily, and then release.The screen guides you through
the Touch - Hold - Release process.
6
Repeat the process three more times in the other three corners of the
screen. A test screen appears.
7
Move your finger across the monitor. The target should move with
your finger. If so, the calibration was successful.
8
Select Accept.
9
On the control panel, select Apply and then select OK.
Note
If the touchscreen still does not appear calibrated, and the
cursor moves vertically when your finger moves horizontally
on the screen or vice versa, the touchscreen cable may not
be connected to the motherboard properly. Call a Parker
technical support representative.