54
Appendix 1 Zoom Table of Function Code
Note: √indicating that function code can be modified and both in stop and run state, and can be copied in stop state.
* indicating that the function code can only be modified by manufacture.
×indicating that function code can only be modified in stop state, and can not be copied.
△
indicating that function code can only be checked but can not be modified.
●indicating that function code is valid only after re-power on
Function
code
Function definition
Setting range
Mfr’s value
Change
Copy
all
Copy
in
part
F100
User’s Password
0
~
9999
8
√
╳
╳
F102
Rated Current
2
~
800
Subject to model
*
╳
╳
F103
Rated Power
Subject to model
Subject to model
*
╳
╳
F105
Software Edition No.
1.00
~
10.00
Subject to model
*
╳
╳
F107
Password Valid or Not
0
:
invalid 1
:
valid
0
√
√
√
F108
Setting User’s Password
0
~
9999
8
√
√
√
F111
Max Frequency
F113
~
590.0Hz
166.6Hz
√
√
√
F112
Min Frequency
0.00Hz
~
F113
0.00Hz
√
√
√
F113
Target frequency in speed
mode
F111
~
F112
1.00Hz
√
√
√
F114
Acceleration Time
0.001
~
32.00S
Subject to model
√
√
√
F115
Deceleration Time
0.001
~
32.00S
Subject to model
√
√
√
F131
Running display items
0
:
present output
frequency/
function code;
1
:
current output rotary
speed;
2
:
output current;
4
:
output voltage;
8
:
PN voltage;
32:
servo
drive
temperature
64: motor temperature
128: given pressure
256: feedback pressure
0+1
+
2
+
4
+
8+64
=
79
√
√
√
F132
display of stop
0
:
frequency/function
code;
2
:
target rotary speed;
4
:
PN voltage;
8
:
motor poles position;
16
:
servo drive temperature
32: motor temperture
2
+
4+8+32
=
46
√
√
√