5.5 Panel Display
Items and Remarks Displayed on the Panel
Items
Remarks
-HF-
It indicates servo drive is resetting.
OC, OE, OL1, OL2,
OH, ESP, ESP1, LU,
PF1,
PP-1,
PP-2,
PGo,
Tro,
AL05,
AL14, ERR2, ERR3
Fault code, indicating “over-current ”, “over-voltage”, “servo drive over-load”,
“motor over-load”, “servo drive over-heat”, "motor over-heat", “Emergency
stop”, “under-voltage protection”, “out-phase for input”, “pressure sensor
fault”, “Pump reversal running fault”, “Resolver fault”, “KTY84
disconnected”, “Resolver pole position fault”, “Braking unit fault”,
“identification
of
motor
parameter
fault”,
“over-current
before
running”respectively.
H.H.
Interruption code, indicating “external interruption” signal input and showing
“0” after reset.
TEST
Motor pole position study.
F100
Function code (parameter code).
10.00
Indicating servo drive running frequency and parameter setting values, etc.
1800
Indicating speed of servo motor
Will flash in Stop condition to display target frequency.
A100
、
U100
Output current (100A) and output voltage (100V). Keep one digit of decimal
when current is below 100A.
u540
DC bus voltage between P- (540V)
H26
The temperature internal servo drive is 26
℃
h26
The temperature internal servo motor is 26
℃
P140
Control board set pressure (bar)
P. 140
Feedback value of pressure sensor. (bar)