Note:
1.
Indicating default value that can not to be modified.
2.
One of CAN communication, 485 communication and analog control can be selected for combined
control. CAN communication is recommended for three or more pumps.
3.
In communication mode, before changing master and auxiliary pump related device, please
disconnect communication cable between master pump and auxiliary pump.
4.
The maximum speed of master, auxiliary pump motor should be corresponding with oil pump’s
speed.
5.
Set master pump and auxiliary pump parameters separately and study poles position.
6.
If there are multiple auxiliary pumps and all auxiliary pumps run at same speed, set total capacity
of auxiliary pumps to FC03. If minimum number of auxiliary pumps is determined by flow, set
each auxiliary pump’s capacity to FC03
~
FC08.
5.6.8.2 Multiple pump combined control diagram