D-52
A p p e n d i x D : P r o g r a m m i n g
AC890PX AC Drive
Parameter Descriptions
USER FREQ 1 to 10
PREF: 21.10, 21.12, 21.14, 21.16,
21.18, 21.20, 21.22, 21.24,
21.26,21.28
Default: Refer to Parameter Table Range: 0.0 to 100.0 %
These parameters provide 10 frequency points, which together with the USER VOLTAGE parameters, provide the user defined voltage profile.
(USER FREQ n, USER VOLTAGE n) provide up to 10 (x,y) points on this profile. The USER FREQ parameters are defined as a percentage of the
BASE FREQUENCY parameter (refer to the MOTOR INDUCTION function block).
USER VOLTAGE 1 to 10
PREF: 21.9, 21.11, 21.13, 21.15,
21.17, 21.19, 21.21, 21.23,
21.25,21.27, 21.29
Default: Refer to Parameter Table Range: 0.0 to 100.0 %
These parameters provide 10 voltage points, which together with the USER FREQ parameters, provide the user defined voltage profile. (USER
FREQ n, USER VOLTAGE n) provide up to 10 (x,y) points on this profile. The USER VOLTAGE parameters are defined as a percentage of the
MOTOR VOLTAGE parameter (refer to the MOTOR INDUCTION function block).
Содержание AC890PX Series
Страница 8: ......
Страница 12: ...1 4 C h a p t e r 1 G e t t i n g S t a r t e d AC890PX AC Drive...
Страница 17: ...C h a p t e r 2 P r o d u c t O v e r v i e w 2 5 AC890PX AC Drive 890PX bottom wire entry...
Страница 22: ...2 10 C h a p t e r 2 P r o d u c t O v e r v i e w AC890PX AC Drive...
Страница 74: ...4 8 C h a p t e r 4 A s s o c i a t e d E q u i p m e n t AC890PX AC Drive...
Страница 96: ...5 22 C h a p t e r 5 O p e r a t i n g t h e D r i v e AC890PX AC Drive...
Страница 162: ...8 22 C h a p t e r 8 T r i p s F a u l t F i n d i n g AC890PX AC Drive...
Страница 170: ...9 8 C h a p t e r 9 R o u t i n e M a i n t e n a n c e R e p a i r AC890PX AC Drive...
Страница 286: ...D 84 A p p e n d i x D P r o g r a m m i n g AC890PX AC Drive Functional Description...