![Parker AC890PX Series Скачать руководство пользователя страница 328](http://html2.mh-extra.com/html/parker/ac890px-series/ac890px-series_engineering-reference_3836877328.webp)
D-126
A p p e n d i x D : P r o g r a m m i n g
AC890PX AC Drive
RESOLVER
SETUP::MOTOR CONTROL::RESOLVER
Designed for PMAC Control Mode.
This block defines the parameters used to set up the resolver.
Parameter Descriptions
NAME
PREF: 133.01
Default: PARVEX
Range:
Set the resolver’s name.
POLES
PREF: 133.02
Default: 2
Range: 2 to 20
Set the resolver’s number of poles. For a standard resolver, this number is 2.
When using a feedback encoder (either resolver or ENDAT encoder) with a belt-pulley system on the feedback (typically PARVEX Torque motors),
this parameter is used to declare the ratio between the motor shaft and the encoder.
For example :
ENCODER RATIO
POLES
Resolver Direct
Mounting
2
Direct Mounting
2
3:1 6
6:1 12
ENDAT Encoder
9:1 18
Содержание AC890PX Series
Страница 8: ......
Страница 12: ...1 4 C h a p t e r 1 G e t t i n g S t a r t e d AC890PX AC Drive...
Страница 17: ...C h a p t e r 2 P r o d u c t O v e r v i e w 2 5 AC890PX AC Drive 890PX bottom wire entry...
Страница 22: ...2 10 C h a p t e r 2 P r o d u c t O v e r v i e w AC890PX AC Drive...
Страница 74: ...4 8 C h a p t e r 4 A s s o c i a t e d E q u i p m e n t AC890PX AC Drive...
Страница 96: ...5 22 C h a p t e r 5 O p e r a t i n g t h e D r i v e AC890PX AC Drive...
Страница 162: ...8 22 C h a p t e r 8 T r i p s F a u l t F i n d i n g AC890PX AC Drive...
Страница 170: ...9 8 C h a p t e r 9 R o u t i n e M a i n t e n a n c e R e p a i r AC890PX AC Drive...
Страница 286: ...D 84 A p p e n d i x D P r o g r a m m i n g AC890PX AC Drive Functional Description...