A p p e n d i x D : P r o g r a m m i n g
D-123
AC890PX AC Drive
Parameter Descriptions
FAST STOP MODE
PREF: 102.05
Default: 0
Range: See below
Selects stopping mode used during a fast stop, two options ramped or coast.
Enumerated Value
:
Stopping Mode
0 : RAMPED
1 : COAST
FAST STOP LIMIT
PREF: 102.06
Default: 30.0 s
Range: 0.0 to 3000.0 s
Maximum time that the Drive will try to Fast Stop, before quenching.
FAST STOP TIME
PREF: 102.07
Default: 0.1 s
Range: 0.0 to 600.0 s
Rate at which the SPEED DEMAND is ramped to zero (see REFERENCE function block)
FINAL STOP RATE
PREF: 102.08
Default: 1200 Hz/s
Range: 1 to 4800 Hz/s
Rate at which any internally generated setpoint trims are removed. For example, the trim due to the slip compensation in Volts/Hz control mode.
Содержание AC890PX Series
Страница 8: ......
Страница 12: ...1 4 C h a p t e r 1 G e t t i n g S t a r t e d AC890PX AC Drive...
Страница 17: ...C h a p t e r 2 P r o d u c t O v e r v i e w 2 5 AC890PX AC Drive 890PX bottom wire entry...
Страница 22: ...2 10 C h a p t e r 2 P r o d u c t O v e r v i e w AC890PX AC Drive...
Страница 74: ...4 8 C h a p t e r 4 A s s o c i a t e d E q u i p m e n t AC890PX AC Drive...
Страница 96: ...5 22 C h a p t e r 5 O p e r a t i n g t h e D r i v e AC890PX AC Drive...
Страница 162: ...8 22 C h a p t e r 8 T r i p s F a u l t F i n d i n g AC890PX AC Drive...
Страница 170: ...9 8 C h a p t e r 9 R o u t i n e M a i n t e n a n c e R e p a i r AC890PX AC Drive...
Страница 286: ...D 84 A p p e n d i x D P r o g r a m m i n g AC890PX AC Drive Functional Description...