D-248
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
PREF Name
Block
Type
Range
Default
ro\rw Notes
133.04 SPEED MAX
RESOLVER
INT
0 to 2147483647
10000
rw
2
133.05 ACCURACY
RESOLVER
REAL
0.00 to 60.00
20.00
rw
2
133.06 CARRIER
VOLTAGE
RESOLVER
REAL
1.00 to 10.00 V
7.00 V
rw
2
133.07 CURRENT
RESOLVER
REAL
0.000 to 0.100 A
0.046 A
rw
2
133.08 INERTIA
RESOLVER
REAL
10.00 to
32768.00Kg.cm2
24.00Kg.cm2
rw
2
133.11 POSITION SET UP
RESOLVER
REAL
-180.00 to 180.00 deg
0.00 deg
rw
133.15 RESOLVER POS
OUT
RESOLVER
REAL
_.xxxx
0.0000
ro
Output
133.16 TRIP
RESOLVER
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
133.17 INIT DONE
RESOLVER
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
133.18 REVERSE CNT DIR RESOLVER
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
2
133.19 SPEED FILTER
RESOLVER
REAL
10.00 to 1000.00 Hz
100.00 Hz
rw
133.20 PHASE SHIFT
RESOLVER
REAL
0.00 to 180.00 deg
0.00 deg
rw
133.21 TRIP SELECTION
RESOLVER
ENUM
0 : HARD AND SOFT
1 : HARD
2 : SOFT
SOFT
rw
133.26 RESET LINE
COUNT
RESOLVER
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
133.27 LINE COUNT X4
RESOLVER
INT
_
0
ro
Output
133.28 PULLEYBELT
RATIO
RESOLVER
INT
1 to 100
1
rw
2
134.01 MANUFACTURER
MOTOR PMAC 1
STRING max length is 16 chars
rw
2
134.02 MODEL
MOTOR PMAC 1
STRING max length is 16 chars
rw
2