Keypad Menus
10-28
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
QUICK SETUP MENU
890CD Common Bus Drive & 890SD Standalone Drive
PREF
6901 Display
Description
Range
Default
27.17
(induction
motor
only)
ROTOR TIME
CONST
This parameter contains the motor model
rotor time constant as determined by
Autotune.
10.00 to 3000.00ms product code
dependent
78.01
SPEED PROP GAIN Sets the proportional gain of the loop.
Speed error (mechanical rev/s) x proportional
gain = torque percent.
0.0 to 3000.0
20.0
78.02
SPEED INT TIME
This is the integral time constant of the speed
loop. A speed error which causes the
proportional term to produce a torque
demand T, will cause the integral term to also
ramp up to a torque demand T after a time
equal to “speed int time”.
1 to 15000ms
100
1.03
AIN 1 TYPE
Selects input range for Analog Input 1.
0 = -10..+10 V
1 = 0..+10 V
0
2.03
AIN 2 TYPE
Selects input range for Analog Input 2.
0 = -10..+10 V
1 = 0..+10 V
0
3.03
AIN 3 TYPE
Selects input range for Analog Input 3.
0 = -10..+10 V
1 = 0..+10 V
2 = 0..20 mA
3 = 4..20 mA
0