Programming
D-193
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
PREF Name
Block
Type
Range
Default
ro\rw Notes
6.01
VALUE
ANALOG OUTPUT
1
REAL
-300.00 to 300.00 %
0.00 %
rw
1
6.05
TYPE
ANALOG OUTPUT
1
ENUM
0 : -10..+10 V
1 : 0..+10 V
0..+10 V
rw
7.01
VALUE
ANALOG OUTPUT
2
REAL
-300.00 to 300.00 %
0.00 %
rw
1
7.05
TYPE
ANALOG OUTPUT
2
ENUM
0 : -10..+10 V
1 : 0..+10 V
0..+10 V
rw
8.02
VALUE
DIGITAL INPUT 1
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
9.02
VALUE
DIGITAL INPUT 2
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
10.02 VALUE
DIGITAL INPUT 3
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
11.02 VALUE
DIGITAL INPUT 4
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
12.02 VALUE
DIGITAL INPUT 5
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
13.02 VALUE
DIGITAL INPUT 6
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
14.02 VALUE
DIGITAL INPUT 7
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
15.02 VALUE
DIGITAL INPUT 8
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
16.02 VALUE
DIGITAL INPUT 9
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
17.01 VALUE
DIGITAL OUTPUT
1
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
1
18.01 VALUE
DIGITAL OUTPUT
2
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
1