D-238
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
PREF Name
Block
Type
Range
Default
ro\rw Notes
114.11 PHASE LOSS
REGEN CNTRL
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
114.12 CLOSE
PRECHARGE
REGEN CNTRL
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
114.13 ENABLE DRIVE
REGEN CNTRL
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
114.14 STATUS
REGEN CNTRL
ENUM
0 : INACTIVE
1 : SYNCHRONIZING
2 : SYNCHRONIZED
3 : SUPPLY FRQ HIGH
4 : SUPPLY FRQ LOW
5 : SYNCH FAILED
INACTIVE
ro
Output
114.15 BRAKE MODE
REGEN CNTRL
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
114.18 Iq DEMAND
REGEN CNTRL
REAL
-1.5 to 1.5
0.0
rw
114.19 MAX CURRENT
REGEN CNTRL
REAL
0.0 to 1.5
1.5
rw
114.25 HARDWARE SYNC REGEN CNTRL
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
115.01 INHIBIT
SPD FBK TRIP
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
115.02 THRESHOLD
SPD FBK TRIP
REAL
0.00 to 300.00 %
50.00 %
rw
115.03 DELAY
SPD FBK TRIP
REAL
0.00 to 300.00 s
10.00 s
rw
115.04 TRIPPED
SPD FBK TRIP
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
117.01 OWN ID
FIREWIRE
INT
_
99
ro
Output
117.02 IRM ID
FIREWIRE
INT
_
99
ro
Output
117.03 NUMBER OF
NODES
FIREWIRE
INT
_
0
ro
Output
117.04 CYCLE TIMER
FIREWIRE
INT
_
0
ro
Output
117.05 BUS RESETS
FIREWIRE
INT
_
0
ro
Output