8-33
Operating the Drive
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
Create DSE 890 Application
Use the DSE 890 Configuration Tool to configure the drive for the 4Q Regen application. A suggested
wiring diagram for the 890 control board is shown below.
Programming Port
USB
0V
AIN1
AIN2
AIN1
AIN4
AIN3
AOUT 2
AOUT1
-10V
+10V
24V DC
0V
Daisy-chain
to next drive
24V
Auxiliary Supply
(optional)
HEALTH
24V
0V
24V DC
0V
DOUT3A
DOUT3B
DIN1 - PRECHARGE CLOSED
DIN3 - RUN FORWARD
DIN2 - NOT COAST STOP
DIN5 -
unassigned
DIN4 -
unassigned
DIN7 - REMOTE TRIP RESET
DIN6 - unassigned
DIN9/DOUT2 - CLOSE PRECHARGE
DIN8/DOUT1 - unassigned