4-36
Installation
AC30V Variable Speed Drive
Manual
The IP address may be fixed if required. The DHCP and Auto-IP must both be disabled.
The current IP address of the AC30V may be monitored using the following parameters
0926 IP Address, 0927 Subnet Mask, 0928 Gateway
Address,
found in menu;
Parameters::Base Comms::Ethernet
The state of the Ethernet may be monitored using the parameter
0919 Ethernet State
and from the Ethernet icon on the GKP status bar.
The IP address may be used to access the AC30V via a web browser.
For more information on customizing and troubleshooting the AC30V Ethernet see Chapter 12 – Ethernet.
Information on using the Modbus TCP server can be found in Appendix A - Modbus TCP.