7-8
PPE
890GTR Inverter Power Manual HA502996
Personal Protective Equipment Inspection
All PPE is to be inspected prior to and after each use. If the PPE is damaged, do not use it. Damaged PPE must
be replaced.
Hard Hats
•
Class G (or A) helmets help protect against impact and low-voltage electrical conductors. Shells are proof-tested at
2200 volts of electrical charge.
•
Class E (or B) helmets help protect against impact and high-voltage electrical conductors. Shells are proof-tested
at 20,000 volts.
•
Type 1 Hardhats protect against impacts to the top of the head.
•
Type 2 Hardhats protect the head from top and side impacts.
INSPECTION:
•
The suspension system is not excessively worn
•
The straps are not torn
•
The plastic components are not broken
•
The helmet has not sustained damage from an impact, poor treatment, or excessive use
•
The shell is not dented, cracked or broken
•
The shell has not been damaged by high temperature
•
The shell has not been degraded by UV light (white chalky substance on the surface of the shell)