12
6250 Servo Controller User Guide
6250
18V AC
0V
18V AC
+15V
0V
–15V
0V
RESET
READY
PSU FAULT
UD12 Drive
(UR4 Rack)
G1
G2
VEL2
VEL1
SCREEN
0V
FAULT
EXT.DIS
LSW1
LSW2
SHLD
COM
SHTNC
SHTNO
DFT
AGND
ANI
CMD–
CMD+
DRIVE 1
1
1
PLnC
PL9A
UD12 Drive
+15V, LSW & LSW2
VEL2
VEL1
0V
FAULT
EXT.DIS
↔
↔
↔
↔
↔
↔
6250
SHTNO
CMD–
CMD+
AGND
DFT
SHLD
If a drive fault occurs, you must cycle power to the drives, unless you control RESET
(pin 8 on the PL9 connector) with one of the 6250's general-purpose outputs.
For additional instructions on detecting and reacting to UD rack faults, contact the
Compumotor or Digiplan Applications Department.
NOTE: These connections will
work only if UD12 jumper LK3 is
set to position A (not the factory
default position).
6250
SHLD
COM
SHTNC
SHTNO
DFT
AGND
ANI
CMD-
CMD+
ENCODER 1
DRIVE 1
Z Drive
+5V
A+
A–
B+
B–
Z+
Z–
GND
SHLD
1
13
25
14
ENABLE–
RTI+
RTI–
RTO+
RTO–
GND
Tx
Rx
GND
CHA+
CHA–
CHB+
CHB–
CHZ+
CHZ–
ANALOG–
I/O [1]
INDEXER CONNECTOR
To 6250 Logic Gnd
To 6250 Programmable Output
Pin #7 and #19 are FAULT RESET+ and FAULT
RESET– respectively. These connections are required
if you need to clear a drive fault via the 6250. Activate
the output for no longer than 140ms. If you choose not
to make these connections, you will have to manually
reset the Z Drive anytime a drive fault occurs.
Z Drive
ENABLE–
GND
GND
CHA+
CHA–
CHB+
CHB–
CHZ+
CHZ–
ANALOG–
Indexer Connector
DRIVE FAULT (pin 9)
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
6250
SHTNO
COM
AGND
GND
A–
A+
B+
B–
Z+
Z–
CMD+
CMD–
DFT
NOTE:
Z Drive CHA+ connected to 6250’s A–
Z Drive CHA– connected to 6250’s A+