LT5048 (Iss 9: 11/12)
4
PARAGON 2000 Plus
Users Instructions
SECTION ONE
Introduction Continued
The PARAGON 2000 Plus incorporates a single gas control, which selects ignition pilot,
and main burner low and high settings.
The PARAGON 2000 Plus incorporates a safety device in the form of an Oxygen
Depletion System, which constantly monitors the oxygen in the room and will cause the
fire to switch off if the oxygen level reduces, for instance due to insufficient ventilation or a
blocked flue.
If this repeatedly occurs do not attempt to relight the appliance until a qualified engineer
has checked it, the problem may not be due to lack of air or a defective flue.
Warning:-
This appliance has a naked flame, has with all such fires it is recommended
that a fireguard should be used for the protection of children, the elderly and infirm.
Fireguards should conform to BS 6539 (1984) (Fireguards for use with solid fuel
appliances).
During the normal operation of the fire some black staining may appear on some parts of
the fuel bed. This is quite normal and adds to the appearance of the appliance. However, if
excessive black staining does occur it may be due to the fuel bed being incorrectly laid.
This should be checked prior to contacting a service engineer.
SECTION TWO
Operation
The pilot can be left on or the pilot can be extinguished and relit each time the fire is used.
The appliance Control Knob is positioned behind the fret.
The full lighting procedure is as follows: -
a.
Push knob in as far as possible on gas control.
b.
Turn knob anti-clockwise until a click is heard. The knob will stop at the position
marked
'
'
and a spark should be seen at the tip of the ignition probe. At the same
time the pilot flame should light. KEEP THE KNOB PRESSED IN FOR 20
SECONDS. Should the pilot fail to light, turn the control knob clockwise to the
'
'
position, wait 3 minutes and repeat the procedure.
c.
After lighting the pilot flame the control knob should be allowed to spring out slightly.
This will allow you to turn the knob further anti-clockwise to the position marked
'
'
.
The pilot flame should then ignite the main fire.
d.
It is possible to adjust the height of the flames by turning the control knob between
the positions marked
'
'
and
'
'
. Note that the knob 'latches' in position at either
end of this movement and must be pushed in slightly before it can be turned.
e.
To turn the fire off, depress the knob slightly and turn it to the
'
'
position.
f.
To completely extinguish the fire, depress the knob slightly and turn to
'
'
the
position.
Note: -
If the ignition fails the pilot can be lit with a taper or a match held at the pilot head.