LT5048 (Iss 9: 11/12) 

17 

TENSIONING NUT

CLAMP SCREW

PARAGON 2000 Plus 

Installation Instructions 

 

SECTION NINE 

To Install the Appliance Continued 

 
Fix the fire casing back into the 
opening using the cable fixing 
system as shown in do not cut 
off loose ends of cable after 
fixing, coil and tuck carefully 
behind sides of Refractory 
back 
Note: when using the cable 
fixing kit with the spacer, fix 
and seal the spacer to the rear 
of the appliance flange with the 
screws and foam seal 
provided. 

 
 
 

CHECKING GAS SOUNDNESS 

After  completing  the  gas  connection  to  the  appliance,  check  for  gas  soundness  in 
accordance with current codes of practice. 

 

FUEL BED LAYOUT 
Important:  - 

Refer  to  the  ‘Health  &  Safety  Notice  located  on  page  3  of 

this booklet

 

before cleaning or replacing any refractory material. 

Lay fuel bed as shown in the Users Section of these instructions. 
ENSURE THE FUEL BED IS PLACED AS INDICATED IN THESE INSTRUCTIONS. 

 

 

CHECKING OPERATION OF FIRE 

Remove the screw from the pressure test point on the inlet elbow and fit pressure gauge.  
Turn on gas the appliance.  Purge the air from the appliance by rotating the control to the 
ignition  position,  push  in  to  allow  the  air  in  the  pipework  to  be  purged  and  the  piezo  to 
ignite the pilot.  Check that the electrode is sparking at the gap between the thermocouple 
tip and the electrode, continue until pilot ignition is established.  Depress the control knob 

slightly  and  rotate  anti-

clockwise  until  the  index  symbol  is  aligned  with  the”

.”on  the 

indicator  label,  release  and  allow  the  appliance  to  run  for  a  period  of  approximately  5 
minutes.  Check the inlet pressure is 20 + 1 mbar for Natural Gas (G20) or 37+ 1mbar for 
Propane Gas (G31). 

 

CHECKING PRODUCT CLEARANCE 

Check for satisfactory clearance of combustion products. Close all doors and windows and 
leave fire burning for 5 minutes. Then position a smoke match just into the top of the fire 
opening  and  move  it  left  and  right,  all  the  smoke  must  be  drawn  into  the  flue.  If  spillage 
occurs, allow a further 5 minutes.  Should spillage still occur, remove appliance restrictor 
plate if still fitted and repeat  spillage test. If spillage still occurs turn off the fire and seek 
expert advice. 
 
 
 

Содержание 2000 Plus Xtra

Страница 1: ...SER INSTALLATION MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start using the appliance Keep this booklet handy for future reference This appliance is for use in GREAT...

Страница 2: ...ireplace Requirements 13 Hole in the Wall installations 14 Clearance to Shelf 15 Clearance to Side of Fire 15 Ventilation 15 SECTION NINE To Install the Appliance 15 Examine Flue Chimney 15 Connecting...

Страница 3: ...s and eye protection After handling wash hands and other exposed parts If a vacuum is used for cleaning the fuel bed or cleaning after servicing installation it is recommended that it be of the type f...

Страница 4: ...be checked prior to contacting a service engineer SECTION TWO Operation The pilot can be left on or the pilot can be extinguished and relit each time the fire is used The appliance Control Knob is pos...

Страница 5: ...sits A vacuum cleaner may only be used after the loose components and moulded shapes have been removed CARE SHOULD BE TAKEN TO AVOID CONTACT WITH THE REFRACTORY LINING THIS IS A DELICATE SURFACE AND S...

Страница 6: ...de front support over front edge of fire where the left right front coals meet see below Note the loose coal provided consist of 5 off shaped as coal A 9 off shaped as coal B Separate the coal into th...

Страница 7: ...PARAGON 2000 Plus Users Instructions SECTION THREE Fuel Bed Cleaning and Layout Cont Lay second row of loose coals 3 off B and 2 off A shapes as shown Lay third row of loose coals 2 off B shape and 1...

Страница 8: ...Total 12 PEBBLE LAYOUT WARNING Take great care when positioning the pebbles to avoid marking the black linings Ensure the BASE MATRIX is in position as shown located against the rear edge of the burn...

Страница 9: ...ARAGON 2000 Plus Users Instructions SECTION THREE Fuel Bed Cleaning and Layout Cont Lay one row of pebbles at the front of the fire as shown Lay another row of loose pebbles shown Lay another row of l...

Страница 10: ...re purpose built ventilation but if for any special reason purpose built ventilation is provided it should be checked periodically to ensure freedom from obstruction Ventilation in the Republic of Ire...

Страница 11: ...ernment s Standard Assessment Procedure SAP for energy rating of dwellings SECTION SIX Regulations and Warnings THIS APPLIANCE MUST ONLY BE INSTALLED IN THE GB OR IRELAND Only to be used in sufficient...

Страница 12: ...t The Building Standards Scotland Consolidation Regulations issued by the Scottish Development Office SECTION SEVEN Siting the Appliance The fire can be installed in the following flues and locations...

Страница 13: ...fitted when the appliance is installed in this type of flue Note A brick or stone chimney with a 125 mm 5 ins minimum diameter flue liner conforming to BS 715 may be used Provided a suitable sealing p...

Страница 14: ...tion should be given to the location of the appliance ensuring it is very visible and it should be positioned at a height were it can clearly be seen on approach Frets and Fascias used for HOLE in the...

Страница 15: ...ed too close to the appliance VENTILATION In the United Kingdom no special ventilation bricks or vents are required into the room containing the appliance provided normal adventitious room ventilation...

Страница 16: ...tated to the required position A suitable isolating cock should always be fitted in the supply feed to the fire to facilitate servicing FIXING FIRE INTO OPENING Remove the paper backing from the lengt...

Страница 17: ...nt on the inlet elbow and fit pressure gauge Turn on gas the appliance Purge the air from the appliance by rotating the control to the ignition position push in to allow the air in the pipework to be...

Страница 18: ...The curing effect of heating the fuel bed and other Refractory components will cause an initial odour This is due to the starch used in the manufacturing process and is non toxic Any debris should be...

Страница 19: ...se fuel bed components 4 Lift away carefully both Left hand and right hand front matrix 5 Lift away carefully rear matrix 6 Remove plastic knob from gas control tap 7 Undo and remove four screws from...

Страница 20: ...e REPLACEMENT OF OXY PILOT ASSEMBLY NOTE If the pilot assembly is replaced it must be replaced by an identical unit from the same manufacturer and replaced as a complete unit 1 Repeat operations 1 11...

Страница 21: ...ust be installed by a GAS SAFE registered person 2 The appliance must be used in accordance with the users instructions 3 The appliance must be serviced annually by a GAS SAFE registered person 4 The...

Страница 22: ...ontact the helpdesk Model 2000 Plus Serial No This information can be found on the label attached to the packaging and on the data badge which is located on the appliance flange top right behind trim...

Страница 23: ...irst annual service Engineer Name Gas Safe Registration No Date of Second annual service Engineer Name Gas Safe Registration No Date of Third annual service Engineer Name Gas Safe Registration No Date...

Страница 24: ...LT5048 Iss 9 11 12 24...

Страница 25: ...YOUR DETAILS Name ________________________________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model 2000 Plus Serial No Date of Purchase This information can be fo...

Страница 26: ...LT5048 Iss 9 11 12 26...

Страница 27: ...LT5048 Iss 9 11 12 27...

Страница 28: ...ox Assembly Burner Tray Box Assembly Ceramics Set Part no 5568 Ceramics Set Part no 4989 Fixing kit 0705 includes 4 magnets foam seal Fixing kit 0705 includes 4 magnets foam seal Foam Sealing Strip Fo...

Отзывы: