260mmCRS.
30mm
460mm
FIX 4 OFF EYE
BOLTS IN
POSITIONS SHOWN
PARAGON 2000 Plus
Installation Instructions
SECTION NINE
To Install the Appliance
GAS CONCEALED CONNECTION
If the supply is to be a concealed connection it would be advisable to route 8mm O/D half
hard copper tube to the rear right side of the fireplace opening, taking into account the
requirements of BS 6891 1988 dealing with enclosed pipes. Form the tube so that it enters
the fire via the blind grommet at the rear of the appliance. An 8mm restrictor elbow can be
positioned under the burner assembly on the right-hand side connected to the gas supply
pipe and its outlet connected to the gas appliance.
Note: pipework in the opening of the fireplace to the rear of the appliance must be suitably
wrapped in accordance with the regulations.
GAS CONNECTION FROM THE FRONT
Connections may be made from the front of the appliance from either the left or right in 8-
mm diameter pipe. If a left-hand connection is required the tube should be routed behind
the bezel plate under the gas control tap and onto the inlet elbow. The inlet elbows should
be rotated to the required position. A suitable isolating cock should always be fitted in the
supply feed to the fire to facilitate servicing.
FIXING FIRE INTO OPENING
Remove the paper backing from the length of foam seal and stick it around the rear flange
of fire. If a spacer is going to be used stick the second length (supplied with the spacer kit)
around the rear face of the spacer unit, THE FOAM SEAL MUST BE POSITIONED TO
ENSURE AN AIR TIGHT SEAL WHEN THE APPLIANCE IS FITTED.
NOTE: -
DO NOT USE PERAMENT SEALING COMPONDS
i.e.
SILICON SEALANT
.
THIS COULD CAUSE THE APPLIANCE TO BE DAMAGED WHEN IT IS REMOVED FOR
SERVICING, AND COULD INVALIDATE THE WARRENTY.
If the spacer is not being used, mark position of flange hole in the fireplace front drill and
fix firebox in position with wall plugs and wood screws. If spacer is being used fix the
spacer to the fireplace first with wood screws and wall plugs then screw firebox to spacer
box using screws provided.
OPTIONAL CABLE FIXING SYSTEM (Available on request from PARAGON FIRES)
(for use when fixing to 18" openings
or when it is desirable not to drill the
fireplace fascia) it may
not
be
possible to use the cable fixing
system with some pre-cast flues.
Drill 4 holes in the rear of the
fireplace opening in the position
shown and fix securely the 4 eye
bolt provided with suitable wall plugs
Содержание 2000 Plus Xtra
Страница 24: ...LT5048 Iss 9 11 12 24...