LT5048 (Iss 9: 11/12)
10
PARAGON 2000 Plus
Users Instructions
SECTION FOUR
Important Information
The only user removable parts are: -
The loose pebbles or coals .
The left hand front pebble or coal
shape.
The right hand front pebble or coal
shape.
The base matrix
Cast Fret
Decorative Trim
SECTION FOUR
Important InformationContinued.
Like all appliances incorporating an aerated burner a low frequency noise may be heard,
particularly on the low setting, this is quite normal and does not affect the operation of the
appliance.
Servicing
It is advised that the PARAGON 2000 Plus fire is serviced annually this is more likely to
provide trouble-free operation. A competent person must carry this out, i.e. Gas Safe
Registered Installer in accordance with the current Gas Safety (Installation and Use)
Regulations 1998 (as amended).
The chimney or flue should be checked annually to ensure clearance of combustion
products.
Ventilation in the United Kingdom
This appliance does not normally require purpose-built ventilation but if for any special
reason purpose-built ventilation is provided it should be checked periodically to ensure
freedom from obstruction.
Ventilation in the Republic of Ireland
Must be permanent ventilation and must comply with the rules in force and should be
checked periodically to ensure freedom from obstruction.
General Appliance Care
Any debris from the chimney or flue should be removed from the fuel bed. The fire should
be allowed to cool for three to four hours before removing debris.
Rubbish must not be thrown onto the fuel bed under any circumstances. The cast fire front
must be positioned in front of the fire whilst it is burning.
Fret
A Fret must be used with this appliance, and must conform too: -
It must be made from non-combustible material.
Its general construction should enable it to stand firmly across the full width of the
burner.
The design of the fire front (fret) must have a removable ashtray cover (lower section).
The ash tray cover must have
cut-outs and
or holes which provide
ventilation to the underside
of the
burner.
The
effective
area
of
ventilation through the ash
tray
cover must be greater than
1365mm2 (2.12 sq. ins.)