background image

 26

The REN is used to determine the number of devices that may be connected to the
telephone line. Excessive RENs on the line may result in the devices not ringing in
response to an incoming call. In most, but not all areas, the sum of RENs should not
exceed five (5.0). To be certain of the number of devices that can be connected to the
line, as determined by the total RENs, contact the local telephone company.

If your unit causes harm to the telephone network, the telephone company may
discontinue your service temporarily. If possible, they will notify you in advance. But if
advance notice is not practical, you will be notified as soon as possible. You will be
advised of your right to file a complaint with the FCC.

Your telephone company may make changes in facilities, equipment, operations, or
procedures that could affect the proper operation of your equipment. If so, you will be
given advance notice so as to give you an opportunity to maintain uninterrupted
service.

No repairs may be performed by the user. Should you experience difficulty with this
equipment, refer to the

 Warranty, Sales, Service, and Training Information on page 28.

Make the T1 network connection using a Universal Service Order Code (USOC) type
RJ48C jack for single-line installations and type RJ48H jack for multiline installations.
Specify both the Service Order Code 6.0F, as well as the proper Facility Interface
Code, to the telephone company when ordering the T1 line. The T1 equipment can be
configured to support any of the framing format and line signaling techniques shown in
the table below. The T1 equipment’s configuration must correspond to the T1 line’s
parameters.

T1 Facility Interface Codes

Interface Code

Description

04DU9-BN

1.544 Mbps superframe format (SF) without line power

04DU9-DN

1.544 Mbps SF and B8ZS without line power

04DU9-1KN

1.544 Mbps ANSI ESF without line power

04DU-1SN

1.544 Mbps ANSI ESF and B8ZS without line power

Make the ISDN PRI connection using a USOC-type RJ48C jack. When ordering an
ISDN line from the telephone company, specify the following:

Service Order Code 6.0F

Facility Interface Code 04DU-1SN

Up to 23B Service for an ISDN PRI DBM – Supports up to 23 circuit-switched
B-channels, with one local phone number for the entire T1 network connection.

Circuit Switched Data capability should be specified.

Содержание FrameSaver SLV

Страница 1: ...ical Manuals FrameSaver Frame Relay Devices Select the following document 9128 A2 GB20 FrameSaver SLV 9126 9128 User s Guide To request a paper copy of a Paradyne document Within the U S A call 1 800...

Страница 2: ...28 A2 GL10 Visit the Paradyne World Wide Web site at www paradyne com to register your warranty Select Service Support Warranty Registration Safety Instructions Please refer to the EMI Warnings and Im...

Страница 3: ...ectly behind the NAM that it supports in the access carrier 1 Remove the I O card from the shipping box To avoid damaging the card handle by the top and bottom edges only 2 At the rear of the carrier...

Страница 4: ...the top and bottom edges to avoid damaging the card 2 At the front of the carrier align the NAM with the upper and lower tracks of the appropriate slot 3 Slide the NAM into the tracks until it seats...

Страница 5: ...to 1 Flow Control is set to None 2 Insert the 8 pin end of the cable into the COM port for the appropriate slot 3 Insert the other end of the cable into the VT100 compatible asynchronous terminal PC...

Страница 6: ...arrow key twice so the cursor is on Configuration 2 Press Enter to display the Configuration menu The Load Configuration From menu appears 3 Press Enter to select Current Configuration The cursor is a...

Страница 7: ...installation time will be increased Verifying that Self Test Passed Before starting to configure the FrameSaver unit confirm that the unit passed the self test 1 Follow this menu selection sequence f...

Страница 8: ...tic Frame Relay Discovery Configuration Set up Automatic Backup Configuration if an ISDN DBM if installed Setting the System Clock To set up the system clock 1 Select Date Time Main Menu Control Date...

Страница 9: ...nually configured Use the following procedure if additional network time slots need to be cross connected to the DSX 1 interface See Assigning Time Slots in Configuration Options of the User s Guide t...

Страница 10: ...ssary 8 Save the configuration Setting Up the Modem FrameSaver 9126 and 9128 units have an integral modem for remote management It is already set up for dial in access to the unit with Port Use set to...

Страница 11: ...se dialing unless B specified T for tone dialing unless B specified Space underscore _ comma for a 2 second pause and dash readability characters 4 Save the phone number s 5 Select SNMP Traps Configur...

Страница 12: ...r the data port Configuration Data Ports DLCI Records 2 Save the configuration and return to the Configuration Edit Display menu 3 Select Management PVC Configuration Management and Communication Mana...

Страница 13: ...ation is enabled For each DLCI discovered on the network a multiplexed network DLCI and a standard port DLCI will be configured and connected EDLCI 0 creating a PVC within the FrameSaver unit No manag...

Страница 14: ...active This feature should be disabled for the central site unit but enabled for the remote unit Automatic backup can be changed at any time via the Auto Backup Criteria configuration options Specific...

Страница 15: ...e 2 Insert the other end of the cable into the RJ48C modular jack Connecting to an M66 Block Use the optional T1 mass termination cable to connect up to seven NAMs to an M66 block The T1 mass terminat...

Страница 16: ...eSaver 9126 supporting up to 2 B channels An ISDN PRI DBM may be installed in a FrameSaver 9128 supporting up to 23 B channels The following guidelines apply Central site configuration guidelines Conf...

Страница 17: ...ter 5 Set up the ISDN Link Profiles Name for the destination entered e g Tampa The default setting is HQ_Site Link Status is set to Auto Phone numbers entered Originating FrameSaver Unit Answering Fra...

Страница 18: ...nit is connected to the network SNMP Trap Managers can be configured To enter SNMP managers 1 Select SNMP Traps configuration options Main Menu Configuration Management and Communication SNMP Traps 2...

Страница 19: ...remote site unit run an IP Ping test to ping the NMS at the central site and verify that the entire path from the remote unit to the NMS is functioning To run the IP Ping test NMS trap managers must...

Страница 20: ...of the cable into the modem service RJ11C jack Connecting to the ISDN 1 Insert the 8 pin connector on the ISDN cable into the MDM interface 2 Insert the other end of the cable into the ISDN service RJ...

Страница 21: ...page 10 Otherwise refer to the status information in Displaying System Information of the User s Guide Check the ISDN Setup 1 Verify the ISDN lines by checking the DBM Interface Status Main Menu Statu...

Страница 22: ...service provider 2 Check Health and Status messages in the left column of the System and Test Status screen to verify that there are no DSX 1 Health and Status messages Main Menu Status System and Tes...

Страница 23: ...e counts that are displayed In the User s Guide see Displaying System Information for additional status information and Troubleshooting for additional troubleshooting information Check PVC Connections...

Страница 24: ...to dangerous high voltage points or other risks Refer all servicing to qualified service personnel 6 General purpose cables are provided with this product Special cables which may be required by the r...

Страница 25: ...nditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Paradyne In order to maintain compliance with FCC limits...

Страница 26: ...ent refer to the Warranty Sales Service and Training Information on page 28 Make the T1 network connection using a Universal Service Order Code USOC type RJ48C jack for single line installations and t...

Страница 27: ...of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with the above conditions may not pre...

Страница 28: ...representative Within the U S A call 1 800 870 2221 Outside the U S A call 1 727 530 2340 Document Feedback We welcome your comments and suggestions about this document Please mail them to Technical...

Отзывы: