13
Setting Up Automatic Frame Relay Discovery Configuration
The default frame relay discovery mode is 1MPort. No auto-configuration occurs until
the network cable is connected. If you do not want management links configured or
auto-configuration, change the default setting for the FR Discovery feature.
The following table describes the difference between the various settings.
FR Discovery Mode
Description
1MPort
(Default)
Auto-configuration is enabled, and for each DLCI
discovered on the network, a multiplexed network DLCI
and a standard port DLCI will be configured and
connected.
The multiplexed network DLCI will contain one EDLCI for
management traffic (EDLCI/2), and one EDLCI for
customer data (EDLCI/0). The customer data EDLCI on
the network will be cross-connected to the data port
DLCI.
1Port
Auto-configuration is enabled. For each DLCI discovered
on the network, a multiplexed network DLCI and a
standard port DLCI will be configured and connected
(EDLCI/0), creating a PVC within the FrameSaver unit.
No management DLCIs will be configured on the network
interface.
2MPorts
Auto-configuration is enabled on both Port-1 and
Port-2.
A management PVC is configured on EDLCI/2.
A multiplexed network DLCI containing three EDLCIs
is configured for Port-1 customer data (EDLCI/0),
Port-2 customer data (EDLCI/1), and management
data (EDLCI/2).
PVC connections are configured between the network
and port DLCIs.
NetOnly
Auto-configuration is enabled, DLCIs are discovered on
the network interface, but no cross-connections are
configured.
Disable
No frame relay discovery takes place. No DLCIs will be
configured on the network interface. The user must
manually configure DLCIs and PVC connections.
See
Using Auto-Configuration in Typical Applications and Setting Up Automatic
Configuration in Setup of the User’s Guide for more information.