2. BitStorm 1900 Installation and Testing
2-60
BitStorm 1900 Installation and Maintenance Guide
1900-A2-GN20-00
Step
Procedure
(continued)
4.)
Connect one Amp-Champ connector of an intermediate cable to
the "Line/CPE" side of the EtherLoop cross-connect block, then
connect the other end to an Amp-Champ to Dual Omni Grid cable.
5.)
Connect the Amp-Champ connector of the second intermediate
cable to the "Voice" side of the EtherLoop cross-connect block,
then connect the other end to an Amp-Champ to Dual Omni Grid
cable.
6.)
Connect the two Omni-Grid connectors from the EtherLoop "Line/
CPE" side to the "Dial Tone & EtherLoop OUT" ports of the filter
shelf as shown in Figure 2-12, "Line/CPE and Voice Connections
on the Filter Shelf for 10306 Modem Cards," on page 61.
7.)
Connect the two Omni-Grid connectors from the "Voice" side to the
"Dial Tone IN from PBX/PSTN" ports of the filter shelf as shown in
Figure 2-12, "Line/CPE and Voice Connections on the Filter Shelf
for 10306 Modem Cards," on page 61, and Figure 2-13, "Line/CPE
and Voice Connections on the Filter Shelf for 10224 Modem
Cards," on page 62. Record EtherLoop assignments.
Содержание BitStorm IP DSLAM 1900
Страница 1: ...BitStorm 1900 IP DSLAM Installation and Maintenance Guide Document No 1900 A2 GN20 00 July 2002...
Страница 12: ...List of Tables viii BitStorm 1900 Installation and Maintenance Guide 1900 A2 GN20 00...
Страница 16: ...About This Document xii BitStorm 1900 Installation and Maintenance Guide 1900 A2 GN20 00...
Страница 48: ...1 BitStorm 1900 IP DSLAM 1 32 BitStorm 1900 Installation and Maintenance Guide 1900 A2 GN20 00...
Страница 148: ...Appendix B Cabling Specifications B 132 BitStorm 1900 Installation and Maintenance Guide 1900 A2 GN20 00...