background image

C

 July 

2002

1900-A2-GN20-00

EMI Notices

UNITED STATES – EMI NOTICE:

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant 
to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful 
interference when the equipment is operated in a commercial environment. This equipment generates, 
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the 
instruction manual, may cause harmful interference to radio communications. Operation of this equipment 
in a residential area is likely to cause harmful interference in which case the user will be required to 
correct the interference at his own expense.

The authority to operate this equipment is conditioned by the requirements that no modifications will be 
made to the equipment unless the changes or modifications are expressly approved by Paradyne 
Corporation.

CANADA – EMI NOTICE:

This Class A digital apparatus meets all requirements of the Canadian interference-causing equipment 
regulations.

Cet appareil numérique de la classe A respecte toutes les exigences du réglement sur le matérial 
brouilleur du Canada.

CE Marking

When the product is marked with the CE mark on the equipment label, a supporting Declaration of Conformity may be 
downloaded from the Paradyne World Wide Web site at www.paradyne.com. Select Library 

 Technical Manuals 

 

CE Declarations of Conformity

.

Japan

Class A ITE

This is a Class A product based on the standard of the Voluntary Control Council for interference by Information 
Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When 
such trouble occurs, the user may be required to take corrective actions.

!

!

Содержание BitStorm IP DSLAM 1900

Страница 1: ...BitStorm 1900 IP DSLAM Installation and Maintenance Guide Document No 1900 A2 GN20 00 July 2002...

Страница 2: ...and Training Information Contact your local sales representative service representative or distributor directly for any help needed For additional information concerning warranty sales service repair...

Страница 3: ...nfigured for DC output connect the product to a 48 VDC SELV supply source that is electrically isolated from the ac source The 48 VDC source is to be reliably connected to earth Connect the earthing g...

Страница 4: ...by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Paradyne Corporation CANADA EMI NOTICE This Class A digital appara...

Страница 5: ...ew 1 1 The BitStorm 1900 System Components 1 1 BitStorm 1900 Shelf 1 2 Air Baffle 1 3 Fan Tray 1 3 Filter Shelf Option 1 3 Filter 66 Block Option 1 4 CO Modem Cards 1 6 Privacy Management 1 6 Same Car...

Страница 6: ...1900 Component Requirements 1 31 2 BitStorm 1900 Installation and Testing Installation Flowchart 2 34 Installation Task List 2 35 Installing the BitStorm 1900 2 35 Task 0013 Pre Installation Checklist...

Страница 7: ...Data Network Equipment Configuration 3 104 Equipment Failure 3 104 Maintenance Checklists 3 105 Voice Data Connectivity Troubleshooting Checklist 3 105 End to End Maintenance Checklist 3 106 Appendix...

Страница 8: ...s B 119 Decapus Cable B 120 AMP Champ to Dual AMP Champ Cable B 121 AMP Champ to Dual Omni Grid Cable B 123 Omni Grid to Dual Omni Grid B 125 Omni Grid to Omni Grid Cable B 127 Intermediate Cable Spec...

Страница 9: ...ay 2 40 Figure 2 4 110 V AC Fan Tray 2 40 Figure 2 5 BitStorm 1900 Modem Shelves Mounted in Bay 2 44 Figure 2 6 BitStorm 1900 Shelf Fastened to Bay 2 45 Figure 2 7 Filter Shelf Mounting in Bay 2 46 Fi...

Страница 10: ...Menu C 135 Figure C 5 A Configuration B SNMP Configuration Menu A SNMP Trap Polling Parameters C 135 Figure C 6 A Configuration B SNMP Configuration Menu B Change SNMP Community Names C 136 Figure C...

Страница 11: ...Shelf Processor 2 54 Table 2 2 Pin and Pair Assignments for the Champ to Omni Grid Cable Part 04 00007 10 2 59 Table 2 3 CLI Command Line Interface Commands 2 76 Table 3 1 Voice Data Connectivity Main...

Страница 12: ...List of Tables viii BitStorm 1900 Installation and Maintenance Guide 1900 A2 GN20 00...

Страница 13: ...anuals BitStorm DSL Systems or GrandVIEW StormTracker EMS Other supporting documentation for the BitStorm 1900 includes 1900 A2 GK40 BitStorm 1900 IP DSLAM Supported SNMP MIBs This document lists supp...

Страница 14: ...nt the following labels will be displayed to indicate safety issues Make sure to read the labels carefully to ensure your own personal safety as well as that of equipment and customer services CAUTION...

Страница 15: ...uired to type or enter will appear in the document as follows ENTER Name Tab programs seven aa1 Text displayed on a computer screen will appear as follows From the HyperTerminal window select File Pro...

Страница 16: ...About This Document xii BitStorm 1900 Installation and Maintenance Guide 1900 A2 GN20 00...

Страница 17: ...criber Line Access Multiplexer IP DSLAM that directs IP data traffic flow between StormPort CPE modems and a data network The BitStorm 1900 is the backbone component of an EtherLoop Intelligent Ethern...

Страница 18: ...ach BS1900 Shelf contains 13 card slots housing the following circuit packs Ten 10 BitStorm Multiplexer Modem Cards Management Interface Unit MIU Power Card Blank Filler Card The blank filler card is...

Страница 19: ...ne BS1900 system is installed in a rack the Air Baffle prevents the heated exhaust air of one BS1900 system from being drawn into the shelf of the BS1900 system installed above Fan Tray The Fan Tray p...

Страница 20: ...the Filter 66 Block integrates a 66 Block with a PCB Printed Circuit Board Filter eliminating the need for a Filter Shelf saving rack space and reducing the number of cables necessary for the install...

Страница 21: ...s chapter covers features of the BitStorm System and the CO modem card and component specifications For further technical information on the BitStorm 1900 System refer to Appendix A section BS1900 Sys...

Страница 22: ...internet or a local server in the StormPort CPE modem Privacy Management filter table The Privacy Management ensures that downstream packets are discarded unless they are from one of the MAC addresse...

Страница 23: ...modems are recognized as having the feature enabled or disabled Table 1 2 Same Card Broadcast Feature Enabled Disabled Function for CO Modems CO Modem Enabled Disabled Feature Function Security 10306...

Страница 24: ...s feature is enabled all nearby EtherLoop lines running high speed video downstreams are protected All CO modems at a site are required to have the feature enabled by StormTracker Site Manager or EMS...

Страница 25: ...P Simple Network Management Protocol Through the SNMP agent users can remotely manage and configure modem settings and monitor the performance statistics of all modems in the BitStorm 1900 system The...

Страница 26: ...traffic from disrupting upstream traffic on adjacent EtherLoop lines NOTE The BitStorm 1900 CO modem card ports are provisioned in the CO CPE Add Search functions of the Database module in the StormTr...

Страница 27: ...ovides six EtherLoop lines each with its own dedicated 10 Mbps modem Special Features Same Card Broadcast Spectrum Manager ADSL Protect Spectrum Manager Video Protect Privacy Management IP Multicast O...

Страница 28: ...er 6 lights Card Dimensions 12 H 7RU x 11 D Operation Temperature 5 o C to 40 o C 41 o F to 104 o F Short term Operat ing Temperature 5oC to 50oC 23oF to 122oF Certifications FCC Part 15 Subpart B Cla...

Страница 29: ...connection The 10306 modem creates Port Table data when a client joins a multicast group and forwards the IGMP message upstream through the MIU to an IGMP enabled Switch When the IP Multicast data is...

Страница 30: ...1 BitStorm 1900 IP DSLAM 1 14 BitStorm 1900 Installation and Maintenance Guide 1900 A2 GN20 00 Figure 1 3 10306 IP Multicast Operation 02 17164...

Страница 31: ...ctive members of that IP Multicast group 8 The 10306 replicates and forwards IP Multicast streams ONLY to the ports with subscribing clients 9 When the member clients issues an IGMP Leave the 10306 re...

Страница 32: ...modem card provides 24 statistically multiplexed EtherLoop lines 12 per single 10 Mbps modem NOTE The 10224 is recommended for use on loops up to 6000 long WARNING POSSIBLE EQUIPMENT DAMAGE To comply...

Страница 33: ...r Link Data Transfer 2 lights Card Dimensions 12 H 7RU x 11 D Operation Temperature 5 o C to 40 o C 41 o F to 104 o F Short term Operat ing Temperature 5 o C to 50 o C 23 o F to 122 o F Certifications...

Страница 34: ...System Power Specifications with 10224 CO Modem Configuration assumes 10 modems cards are used Power Bit Storm 1900 Configuration Modem Cards Lines Power Watts Watts Per Line Watts w Fan Tray Max Curr...

Страница 35: ...lf via an out of band I C configuration channel Thereafter the assigned modems will only respond to commands from the associated MIU via the in band Ethernet connection Modem parameters can also be se...

Страница 36: ...11 connector and cable included Heat Dissipation 4 watts LEDs Power green indicates power is on Alarm red indi cates internal problem with MIU Link for 10Base T X two lights yellow indicates receive t...

Страница 37: ...r Spectrum Manager Etc Modem Cards TCP IP Server can be co located or remote IP Address Mode X Daemon SNMP POWER READY 100Mb s LINK ACT LINK ACT 100Mb s 100Mb s LINK ACT LINK ACT 100Mb s 100Mb s LINK...

Страница 38: ...ards convert the power feeds to the 12 5 3 3 5 and 2 5 V DC power levels used by the BitStorm 1900 components 260 W DC The 260 W DC power card converts the 48 V DC power feed to the power levels used...

Страница 39: ...Input 48V DC Refer to Table 1 3 System Power Specifications with 10306 CO Modem on page 13 and Table 1 4 System Power Specifications with 10224 CO Modem on page 18 Cord Mate n Lock connector 18 includ...

Страница 40: ...d Maintenance Guide 1900 A2 GN20 00 260 W AC The 260 W AC power card converts the 110 220 V AC power feed to the power levels used by the 10603 and 10224 CO modem cards and the MIU Application Require...

Страница 41: ...Description Specification Card Dimensions 12 x 2 27 x 11 75 LEDs 12V DC 5 V DC 3 3V DC 5 V DC Input 85 265 V AC 47 63 Hz Cord IEC 320 6 Operating Temperature 5 o C to 40 o C 41 o F to 104 o F Short t...

Страница 42: ...re 10306 or 10224 CO modem cards Fan Tray 110 220 V AC Figure 1 9 Fan Tray 110 220 V AC Part 01 00084 02 115 230V AC Switch Selectable FUSE 2 AMP 250V AC ON OFF 02 17170 Fan Tray 110 220 V AC Specific...

Страница 43: ...WARNING POSSIBLE EQUIPMENT DAMAGE AC Fan Trays are shipped with an air filter frame To ensure proper airflow the frame must be installed DO NOT install an air filter for the AC Fan Tray only the frame...

Страница 44: ...cifications Operating Temperature 0o C to 40o C 0o F to 104o F Storage Temperature 40o C to 70o C 40o F to 158o F Certifications UL 60950 cUL NEBS Level 3 CE Power Consumption 45W Dimensions 3 5 x 18...

Страница 45: ...ains one filter card for every two 10306 modem cards or two filter cards for every 10224 modem card The filter shelf connects to the distribution frame designed to minimize signal interference and fac...

Страница 46: ...rd Dimensions 4 75 x 1 5 x 11 25 Third Order Low Pass Filters insertions loss 5 dB to 12 kHz 60 kHz stop band loss 30 dB 100 Ohm return loss 20 dB to 12 kHz Certifications UL 60950 cUL NEBs Level 3 CE...

Страница 47: ...wer Yes Yes Must use fan tray Air filter is required for NEBs compliance 01 00079 01 260 W AC power Yes Yes Must use fan tray without an air filter 01 00075 01 MIU Yes Yes 01 00084 01 Fan Tray DC Yes...

Страница 48: ...1 BitStorm 1900 IP DSLAM 1 32 BitStorm 1900 Installation and Maintenance Guide 1900 A2 GN20 00...

Страница 49: ...ment rack Connecting the BitStorm 1900 to the telephone line Installing the StormPort CPE modems Connecting the Ethernet data network NOTE In voice data applications the BitStorm 1900 shelf installati...

Страница 50: ...Air Baffle On Top Are you using a Filter Shelf Install Filter Shelf s on top of BitStorm 1900 Chassis Install appropriate cards into the BitStorm 1900 Verify Power and Connect to BitStorm 1900 Instal...

Страница 51: ...to the next task Task and Description Page Task 001 Pre Installation Checklist 36 Task 002 Installing the 19 Fan Tray 38 Task 003 Installing the BS1900 and Filter Shelves 42 Task 004 Installing the Ai...

Страница 52: ...Refer to Appendix A Installation Requirements on page 107 for specifications 4 Verify you have all necessary tools equipment and materials for the installation Use the following table as a guide Tabl...

Страница 53: ...cuit packs and cables are at the installation site and that they are in good condition If a Materials List is provided verify the packing list with it 6 Determine if an AC or DC power card is to be us...

Страница 54: ...O modem cards The following instructions are for installation of the 48 V DC and 110 220 V AC switch selectable fan trays Step Procedure 1 Seat the fan tray at the bottom of the rack leave room for at...

Страница 55: ...0 V AC fan tray a The 48 V DC connection requires a 14 gauge stranded cable not included b Connect the black power feed to the positive terminal and the red power feed to the negative terminal NOTE Th...

Страница 56: ...cord to the IEC terminal connection on the front panel b Route the other end to a grounded outlet NOTE The power supply for the multiplexer must also be 110 220 V AC Figure 2 4 110 V AC Fan Tray WARN...

Страница 57: ...An air filter must be installed and maintained in the DC Fan Tray for NEBs compliance a Verify filter is installed in the frame b Slide the unit into the fan tray NOTE Installed air filters must be ch...

Страница 58: ...quipment bay with enough space available installed secured and electrically grounded according to standard industry practice specifications for a suitable bay are described in the Appendix A section B...

Страница 59: ...ay as shown in Figure 2 5 BitStorm 1900 Modem Shelves Mounted in Bay WARNING ELECTROSTATIC DISCHARGE Anti static protection required The BitStorm 1900 shelves are shipped with the circuit packs instal...

Страница 60: ...uide 1900 A2 GN20 00 Figure 2 5 BitStorm 1900 Modem Shelves Mounted in Bay 4 Using the shelf mounting screws provided in the shelf hardware kit fasten the left and right flanges to the bay as shown in...

Страница 61: ...ceed according to the following table If the application is Then Voice data Align and mount a filter shelf directly above the Bit Storm 1900 shelf as shown in Figure 2 7 Filter Shelf Mounting in Bay o...

Страница 62: ...m 1900 Installation and Maintenance Guide 1900 A2 GN20 00 Step Procedure continued Figure 2 7 Filter Shelf Mounting in Bay STOP RX KDYH FRPSOHWHG WKLV WDVN Filter Shelf 5 25 x 17 5 x 11 75 BS1900 Shel...

Страница 63: ...all the BitStorm 1900 Air Baffle Requirements This procedure requires the following Phillips head screwdriver 1 or 2 Step Procedure 1 Verify that the mounting adapters are in the same position as the...

Страница 64: ...c protection Step Procedure 1 Place anti static strip on wrist and attach to the grounded rack 2 Remove the circuit pack from the anti static packaging 3 Align the card in the appropriate slot 4 Seat...

Страница 65: ...ed in Appendix A Installation Requirements on page 107 Step Procedure 1 Eject all cards Power MIU Shelf Processor and Modems from the backplane of the shelf Ensure that the cards completely dislodge f...

Страница 66: ...he 48 V DC power supply reversed polarities on the power feed can irreparably damage the BitStorm 1900 shelf components Be certain that power feeds are connected properly to the power source with the...

Страница 67: ...e terminal connection as seen in Figure 2 8 Typical DC Power Harness Connection to 48 V DC 260W Power Source on page 51 NOTE If using a 48 V DC power supply use an appropriate volt ohm meter to test a...

Страница 68: ...the other end of the DC power harness to the DC power connector on the backplane of the BitStorm 1900 modem shelf The connector only fits one way 6 For an AC power supply connect the power cord to th...

Страница 69: ...2 GN20 00 BitStorm 1900 Installation and Maintenance Guide 2 53 Step Procedure continued 9 Secure the power harness in accordance with local office procedures 10 Turn ON the power to the shelf from th...

Страница 70: ...o Table 2 1 Step Procedure 1 Connect one end of the RJ 45 crossed cable to the switch router then route the other end to the 10 Base T X port of MIU Table 2 1 Data Cable Selection for MIU Shelf Proces...

Страница 71: ...Loop data network connection with the BitStorm 1900 using an MIU Figure 2 10 BitStorm 1900 Data Connection via MIU BitStorm 1900 BitStorm Server POWER READY 100Mb s LINK ACT LINK ACT 100Mb s 100Mb s L...

Страница 72: ...DB9S to RJ 11 to the local craft terminal PC laptop Then connect the other end to the RS 232 port on the MIU Refer to Figure 2 11 shown below 4 Verify that the green LED at the EtherLoop hub router p...

Страница 73: ...5 Proceed according to the following table STOP RX KDYH FRPSOHWHG WKLV WDVN If the application is Then Voice data GO TO Task 008 Installing Voice Data Filter Shelf Connections on page 58 OR Task 009...

Страница 74: ...10 BitStorm 1900 cable harnesses 10 intermediate cables 10 BitStorm 1900 data cables Appendix B Cabling Specifications on page 115 contains the specifications for the cables and wiring required in th...

Страница 75: ...30 E4 R6 BLU RED 6 D4 T6 RED BLU 31 B6 R7 OR RED 7 A6 T7 RED OR 32 E6 R8 GR RED 8 D6 T8 RED GR 33 B7 R9 BR RED 9 A7 T9 RED BR 34 E7 R10 SLT RED 10 D7 T10 RED SLT 35 B8 R11 BLU BLK 11 A8 T11 BLK BLU 3...

Страница 76: ...ect the other end to an Amp Champ to Dual Omni Grid cable 6 Connect the two Omni Grid connectors from the EtherLoop Line CPE side to the Dial Tone EtherLoop OUT ports of the filter shelf as shown in F...

Страница 77: ...ne CPE and Voice Connections on the Filter Shelf for 10306 Modem Cards Interconnect Cable 1 IN Not Used Dial Tone IN from PBX PSTN EtherLoop from BitStorm shelf Dial Tone EtherLoop OUT Interconnect Ca...

Страница 78: ...CPE and Voice Connections on the Filter Shelf for 10224 Modem Cards Interconnect Cable 1 IN Not Used Dial Tone IN from PBX PSTN EtherLoop from BitStorm shelf Dial Tone EtherLoop OUT Interconnect Cable...

Страница 79: ...llation and Testing 1900 A2 GN20 00 BitStorm 1900 Installation and Maintenance Guide 2 63 Step Procedure continued 8 Go to Task 011 Installing External Voice Switch Connections on page 70 STOP RX KDYH...

Страница 80: ...cables Cross connect block s of the same type used in the existing main distribution frame MDF Cross connect punch down tool Jumper Wire 24 AWG Appendix B Cabling Specifications on page 115 contains t...

Страница 81: ...0 Installation and Maintenance Guide 2 65 Step Procedure continued Figure 2 14 Voice Data Filter 66 Block Connections for 10306 CO Modems Not Used Amp Champ to Dual Omni Grid Cable part 04 00007 10 Am...

Страница 82: ...00 Installation and Maintenance Guide 1900 A2 GN20 00 Step Procedure continued Figure 2 15 Voice Data Filter 66 Block Connections for 10224 CO Modems STOP RX KDYH FRPSOHWHG WKLV WDVN Not Used J1 J2 Am...

Страница 83: ...ep Procedure 1 Place and secure the dedicated EtherLoop cross connect on the facility main distribution frame 2 Route the Tip Ring pairs originating from the StormPort CPE lines to the EtherLoop cross...

Страница 84: ...17 Data only Connections on the 66 Block for 10224 CO Modem Cards on page 69 Record the EtherLoop assignments Figure 2 16 Data only Connections on the 66 Block for 10306 CO Modem Cards Not Used J1 J2...

Страница 85: ...00 Installation and Maintenance Guide 2 69 Step Procedure continued Figure 2 17 Data only Connections on the 66 Block for 10224 CO Modem Cards STOP RX KDYH FRPSOHWHG WKLV WDVN Not Used J1 J2 Amp Champ...

Страница 86: ...rocedure Step Procedure 1 Identify the existing Tip and Ring jumper connections from the external voice facility cross connect block to the customer premises equipment CPE cross connect block 2 Verify...

Страница 87: ...00 A2 GN20 00 BitStorm 1900 Installation and Maintenance Guide 2 71 Step Procedure continued 8 Record the EtherLoop cross connect Tip Ring assignments for the voice facility according to local office...

Страница 88: ...tStorm 1900 is powered on 2 Verify the PC has an ASCII terminal emulator loaded i e Hyperterminal software etc 3 Connect the PC to the MIU card using the MIU Craft Cable RS 232 to RJ 11 adapter and te...

Страница 89: ...A2 GN20 00 BitStorm 1900 Installation and Maintenance Guide 2 73 Step Procedure continued Figure 2 18 Craft Connection with the MIU Craft Cable MIU Card CRAFT Connection MIU Craft Cable DB 9 with RJ...

Страница 90: ...the serial COM1 port terminal communication settings a Initiate a Terminal Session using terminal emulation software i e Hyperterminal b Select the appropriate serial COM port from the pull down menu...

Страница 91: ...e Craft Interface Login screen displays Type admin for the default Username and press Enter NOTE The Craft Interface is case sensitive Make sure to type all entries in lowercase The following screen d...

Страница 92: ...CLI commands type help at the BS1900MIU prompt and press Enter This screen provides a list of the available commands to configure the MIU Refer to the following table for a description of each com ma...

Страница 93: ...nce Guide 2 77 DATE Enter to change the date HELP Enter to obtain additional help IFCONFIG Use to configure the MIU I P Address Subnet Mask Status Default Gateway etc MENU Enter to view the Main Menu...

Страница 94: ...system It is not advised to power down the system in order to perform a reset of the system SNMP Enter to review and or modify the current SNMP configuration SYSINFO Enter to access and review system...

Страница 95: ...d Testing 1900 A2 GN20 00 BitStorm 1900 Installation and Maintenance Guide 2 79 Step Procedure continued 8 Type menu at the BS1900MIU prompt The BitStorm 1900 MIU Craft Interface Main Menu displays 9...

Страница 96: ...00 Step Procedure continued 10 From the Configuration Menu type a to access the Network Interface Configuration screen 11 Type in the MIU Ethernet IP Address MIU Ethernet Subnet Mask MIU Default Gatew...

Страница 97: ...dure continued 12 Type c to select Set Time of Day Clock The following screen appears 13 Enter the current date and time a Enter the current date in the format MMDDYYYY Enter only the numbers not the...

Страница 98: ...the Time field This field is not marked in this version Enter the time as HHMMSS Do not type the colon between the numbers plus signs will separate the numbers c Press CTRL W to save the changes Press...

Страница 99: ...00 Installation and Testing 1900 A2 GN20 00 BitStorm 1900 Installation and Maintenance Guide 2 83 Step Procedure continued 15 Type a to select Change Username to modify the user name The following scr...

Страница 100: ...ll follow indicating that the user name has been saved Press any key to return to the User Account Administration screen 17 Select Change Password to modify the password The following screens display...

Страница 101: ...Storm 1900 Installation and Maintenance Guide 2 85 Step Procedure continued 19 Once all of the configuration parameters are entered the system must be reset for the changes to take effect To reset the...

Страница 102: ...900 Installation and Testing 2 86 BitStorm 1900 Installation and Maintenance Guide 1900 A2 GN20 00 Step Procedure continued 20 Type a to select Reset System and then y to confirm STOP RX KDYH FRPSOHWH...

Страница 103: ...rm 1900 To access and configure the MIU SNMP function clients will either use an SNMP Network Management Software solution i e EMS 2 x HP OpenView CastleRock s SNMPc etc or Telenet into the MIU and us...

Страница 104: ...nt and private MIBs can be downloaded from the Paradyne website at www paradyne com Using Telnet for Remote Provisioning and Management NOTE Before using the Telnet option for remote management the MI...

Страница 105: ...m 1900 Installation and Maintenance Guide 2 89 Step Procedure continued 2 Type command in the Open field and click OK The DOS prompt displays 3 At the DOS prompt type telnet and the I P Address for th...

Страница 106: ...ation and Maintenance Guide 1900 A2 GN20 00 Step Procedure continued 4 Type admin for the default Username and press Enter NOTE The Craft Interface is case sensitive Make sure to type all entries in l...

Страница 107: ...e 2 91 Step Procedure continued The BS1900MIU prompt displays 6 Type version to check the current firmware version To verify this is the latest version contact our Technical Support organization at ww...

Страница 108: ...pe ifconfig m 0 and press Enter 9 The screen above displays indicating you are connected remotely to the MIU and asks if you would like to change the IP address of the MIU Press y 10 From this screen...

Страница 109: ...Installation and Maintenance Guide 2 93 Step Procedure continued 11 To view the current SNMP parameters type snmp L and press Enter 12 Verify the correct Community Name Poll Intervals and Trap Target...

Страница 110: ...1 as a minimum security control tool much like a user ID and or password For this field enter an identifier of up to 15 alpha characters Current Poll Interval The Current Polling Interval provides the...

Страница 111: ...ystem must be reset Type reset and press Enter then y to confirm NOTE When logging back into the MIU the new IP Address must be entered Refer to Table 2 3 CLI Command Line Interface Commands on page 7...

Страница 112: ...e not included in this document BitStorm 1900 Testing Locations Primary test points for installation include the following Customer premises cross connect containing the connections for the BitStorm 1...

Страница 113: ...100Mb s LINK ACT LINK ACT 100Mb s 100Mb s LINK ACT LINK ACT 100Mb s 100Mb s LINK ACT LINK ACT 100Mb s 1 2 3 4 5 6 7 8 17 18 19 20 21 22 34 24 Layer 2 3 Switch B I T S T R M SERVER PBX Dial Tone In Cr...

Страница 114: ...t Points STOP RX KDYH FRPSOHWHG WKLV WDVN BitStorm 1900 Optional BitStorm Server POWER READY 100Mb s LINK ACT LINK ACT 100Mb s 100Mb s LINK ACT LINK ACT 100Mb s 100Mb s LINK ACT LINK ACT 100Mb s 1 2 3...

Страница 115: ...equipment installed Tip Ring assignments Standard telecommunications hand test telephone set Step Procedure 1 Identify the voice line being tested Turn on the BitStorm 1900 2 Connect the hand test set...

Страница 116: ...is required for this procedure Step Procedure 1 Identify the data connections being tested at the EtherLoop cross connect block and the Modem card on the BitStorm 1900 shelf 2 Install and connect the...

Страница 117: ...lephone test set with RJ 11 connection to the StormPort modem Ethernet 10Base T cable with RJ 45 terminations Laptop personal computer equipped with the following Ethernet PC card configured for TCP I...

Страница 118: ...rm 1900 Maintenance on page 103 for more information 7 In the browser application enter the IP address of a known working site on your network or on the Internet Repeat this step for several sites 8 O...

Страница 119: ...pment installation Improper data network equipment configuration Equipment failure The following sections briefly describe each of these potential problem causes Wiring Conditions In general EtherLoop...

Страница 120: ...s relatively simple to install However if an equipment card is installed in the wrong slot or if the cards are not firmly seated in their backplane connectors the EtherLoop system will not function Da...

Страница 121: ...Check jumper connections Check LEDs at intermediate hub or InterProxy router connections Check for 10Base T cable damage Verify that Modem card is present in correct slot and fully seated in BitStorm...

Страница 122: ...wn Verify that the Ethernet card on the PC connected to the modem has been configured Verify that the correct type of Ethernet cable straight or crossover is being used for the application Verify that...

Страница 123: ...icable 48 V DC or 110 V AC power supply 48 Vdc or 110 220 V AC Fan Shelf if applicable Grounding facility Network support equipment The following sections list the specifications and requirements for...

Страница 124: ...BitStorm 1900 System Specifications shows the power specifications for the BitStorm 1900 shelf Table A 1 BitStorm 1900 System Specifications BitStorm 1900 System Specifications Description Front Mount...

Страница 125: ...rds The grounding environment for the BitStorm 1900 shelf and its supporting bay can be either a Common Bonding Network CBN or an Isolated Bonding Network Connectors 2 Rows of Omni Grid Connectors for...

Страница 126: ...ctor to the collector The collector must then be grounded to the common ground point FGB or BPG using a 2 AWG stranded ground conductor If the distance from the FGB BPG or ground collector is greater...

Страница 127: ...on our Partners site at www paradyne com BS1900 Component Installation Requirements Table A 2 BitStorm 1900 Components lists the component requirements for the BitStorm 1900 Table A 2 BitStorm 1900 Co...

Страница 128: ...3RU 12 filters 1 filter card per two 10306 cards 2 filter cards per 10224 04 00007 10 Champ to Dual Omni Grid 2 per four 10306 cards 2 per 10224 04 00008 18 Omni Grid to Dual Omni Grid 2 per 10224 w...

Страница 129: ...om other machinery and should have a minimum distance of 30 inches from UV lighting to prevent Electrostatic Discharge ESD The BitStorm 1900 should not be installed in laundry rooms workshops janitori...

Страница 130: ...supply 48 V DC nominal 46 to 56 V DC acceptable range or 110 V AC Environmental Operating temperature 5o C 41o F to 40o C 104o F Relative Humidity 1 to 90 Air quality should be good to excellent Elect...

Страница 131: ...cards in the BitStorm 1900 shelf The illustrations associated with each of the modem card cabling sections show typical rack layouts These configurations change according to the particular implementat...

Страница 132: ...6 Modem Cards on page 117 illustrates the connections for the 10306 modem card using a Filter 66 Block Figure B 1 Cabling Filter Shelf with 10306 Modem Cards 10306 10306 10306 2 RU FAN 2 RU AIR BAFFLE...

Страница 133: ...RU FAN 2 RU AIR BAFFLE 2 RU FAN 2 RU AIR BAFFLE 2 RU FAN 2 RU AIR BAFFLE 02 17195 Only one Filter 66 Block and one set of cables are shown 60 total lines are possible per BitStorm 1900 with 10306 car...

Страница 134: ...k with 10224 Modem Cards on page 119 illustrates the connections for the 10224 modem cards using a Filter 66 Block Figure B 3 Cabling Filter Shelf with 10224 Modem Cards 10224 1 RU AIR INTAKE SPACE 2...

Страница 135: ...he BitStorm 1900 cable assembly DSUB50P to 10x RJ45 This cable connects the MIU card to the layer 2 3 switch 2 RU FAN 2 RU AIR BAFFLE 10224 1 RU AIR INTAKE SPACE 2 RU FAN 2 RU AIR BAFFLE 2 RU FAN 2 RU...

Страница 136: ...Cable Figure B 5 Decapus Cable Connections MIU Connector Layer 2 3 Switch Connectors 02 17198 BitStorm 1900 Decapus Cable MIU Card 02 17199 POWER READY 100Mb s LINK ACT LINK ACT 100Mb s 100Mb s LINK...

Страница 137: ...e AMP Champ to Dual AMP Champ cable connects from the Filter 66 Block to an AMP Champ Omni Grid cable which connects to the 10306 cards Refer to Figure B 6 shown below and to Table B 1 AMP Champ to Du...

Страница 138: ...6 38 BK G 26 2 O W 2 14 BR BK 2 27 W O 27 39 BK BR 27 3 G W 3 15 S BK 3 28 W G 28 40 BK S 28 4 BR W 4 16 BL Y 4 29 W BR 29 41 Y BL 29 5 S W 5 17 O Y 5 30 W S 30 42 Y O 30 6 BL R 6 18 G Y 6 31 R BL 31...

Страница 139: ...Block with 10306 and 10224 CO modem cards to the AMP Champ to AMP Champ cable the cross connect For 10306 and 10224 CO modem cards connecting to a Filter 66 Block this cable connects to the AMP Champ...

Страница 140: ...D BLU 31 B6 R7 OR RED 7 A6 T7 RED OR 32 E6 R8 GR RED 8 D6 T8 RED GR 33 B7 R9 BR RED 9 A7 T9 RED BR 34 E7 R10 SLT RED 10 D7 T10 RED SLT 35 B8 R11 BLU BLK 11 A8 T11 BLK BLU 36 E8 R12 OR BLK 12 D8 T12 BL...

Страница 141: ...Dual Omni Grid The Omni Grid to Dual Omni Grid cable is used to connect the Filter Shelf to 10306 CO modem cards Refer to Figure B 8 shown below and Table B 3 Omni Grid to Dual Omni Grid Cable Specif...

Страница 142: ...pecifications J3 J2 Color J1 B2 BLU WHT B2 A2 WHT BLU A2 E2 OR WHT E2 D2 WHT OR D2 B3 GR WHT B3 A3 WHT GR A3 E3 BR WHT E3 D3 WHT BR D3 B4 GRY WHT B4 A4 WHT GRY A4 E4 BLU RED E4 D4 RED BLU D4 B2 OR RED...

Страница 143: ...ni Grid to Omni Grid Cable The omni grid to omni grid cable connects the Filter Shelf to the 10224 CO modem cards Refer to Figure B 9 shown below and Table B 4 Omni Grid to Omni Grid Cable Specificati...

Страница 144: ...ir Color Code To Conn To Pin J1 A2 T1 WHT BLU J2 A2 J1 B2 R1 BLU WHT J2 B2 D2 T2 WHT OR D2 E2 R2 OR WHT E2 A3 T3 WHT GR A3 B3 R3 GR WHT B3 D3 T4 WHT BR D3 E3 R4 BR WHT E3 A4 T5 WHT SLT A4 B4 R5 SLT WH...

Страница 145: ...shelf from a variety of vendors as long as cables chosen meet the following specifications Category 5 bundled 25 pair cable made of 24 AWG wires Unshielded 25 pair female connector Amp Champ or equiva...

Страница 146: ...Cable Harness Power Connector Terminations The end of the BitStorm 1900 power cable assembly that connects to the power source has two red and two black leads Each lead is terminated with 24 4 ring c...

Страница 147: ...ies on the DC power feed can irreparably damage the BitStorm 1900 shelf components Be certain power feeds are connected properly to the power source with the red leads connected to the DC supply as sh...

Страница 148: ...Appendix B Cabling Specifications B 132 BitStorm 1900 Installation and Maintenance Guide 1900 A2 GN20 00...

Страница 149: ...00 BitStorm 1900 Installation and Maintenance Guide C 133 Appendix C Craft Interface Screens This appendix includes all of the Craft Interface screens available from the Main Menu Main Menu Figure C...

Страница 150: ...aft Interface Screens C 134 BitStorm 1900 Installation and Maintenance Guide 1900 A2 GN20 00 Configuration Figure C 2 A Configuration Configuration Menu Figure C 3 A Configuration A Network Interface...

Страница 151: ...rface Screens 1900 A2 GN20 00 BitStorm 1900 Installation and Maintenance Guide C 135 Figure C 4 A Configuration B SNMP Configuration Menu Figure C 5 A Configuration B SNMP Configuration Menu A SNMP Tr...

Страница 152: ...erface Screens C 136 BitStorm 1900 Installation and Maintenance Guide 1900 A2 GN20 00 Figure C 6 A Configuration B SNMP Configuration Menu B Change SNMP Community Names Figure C 7 A Configuration C Se...

Страница 153: ...Appendix C Craft Interface Screens 1900 A2 GN20 00 BitStorm 1900 Installation and Maintenance Guide C 137 Statistics Figure C 8 B Statistics Menu Figure C 9 B Statistics A Network Layer Statistics...

Страница 154: ...face Screens C 138 BitStorm 1900 Installation and Maintenance Guide 1900 A2 GN20 00 Figure C 10 B Statistics B Physical Layer Statistics Menu Figure C 11 B Statistics B Physical Layer Statistics A Eth...

Страница 155: ...aft Interface Screens 1900 A2 GN20 00 BitStorm 1900 Installation and Maintenance Guide C 139 Figure C 12 B Statistics B Physical Layer Statistics B I2C Statistics Figure C 13 B Statistics C Environmen...

Страница 156: ...ndix C Craft Interface Screens C 140 BitStorm 1900 Installation and Maintenance Guide 1900 A2 GN20 00 Figure C 14 B Statistics D System Memory Statistics Figure C 15 B Statistics E Shelf Extent Statis...

Страница 157: ...ix C Craft Interface Screens 1900 A2 GN20 00 BitStorm 1900 Installation and Maintenance Guide C 141 Figure C 16 B Statistics F System Error Reset Data Figure C 17 B Statistics G Modex Daemon Run Stati...

Страница 158: ...Screens C 142 BitStorm 1900 Installation and Maintenance Guide 1900 A2 GN20 00 Firmware Version Information Figure C 18 C Firmware Version Information User Account Administration Figure C 19 D User A...

Страница 159: ...creens 1900 A2 GN20 00 BitStorm 1900 Installation and Maintenance Guide C 143 Figure C 20 D User Account Administration A Change Remote TELENET Username Figure C 21 D User Account Administration B Cha...

Страница 160: ...Appendix C Craft Interface Screens C 144 BitStorm 1900 Installation and Maintenance Guide 1900 A2 GN20 00 Utilities Figure C 22 E Utilities Menu Figure C 23 E Utilities A Reset Confirmation...

Отзывы: