2. BitStorm 1900 Installation and Testing
2-40
BitStorm 1900 Installation and Maintenance Guide
1900-A2-GN20-00
Step
Procedure
(continued)
Figure 2-3: -48 V DC Fan Tray
3.)
Connect power for the 110/220 V AC fan tray.
a.) Connect the power cord to the IEC terminal connection on the
front panel.
b.) Route the other end to a grounded outlet.
NOTE: The power supply for the multiplexer must also be 110/220 V AC.
Figure 2-4: 110 V AC Fan Tray
!
WARNING: POSSIBLE EQUIPMENT DAMAGE! Be sure
to set the switch on the back panel of the
110/220 V AC fan tray to 115 V for a 110 V AC
connection, and 230 V for a 220 V AC
connection. Failure to do so will blow the
fuse on the front panel.