C. Configuration Options
C-12
March
2001
3150-A2-GB24-10
Com Rate: 9.6
Next 1.2 2.4 4.8 9.6 14.4 19.2 38.4 Prev
Communication Port Rate. Configures the bit rate for the communication port.
1.2
–
Sets the bit rate to 1200 bps (for asynchronous operation only).
2.4
–
Sets the bit rate to 2400 bps.
4.8
–
Sets the bit rate to 4800 bps.
9.6
–
Sets the bit rate to 9600 bps.
14.4
–
Sets the bit rate to 14,400 bps.
19.2
–
Sets the bit rate to 19,200 bps.
38.4
–
Sets the bit rate to 38,400 bps. This rate is not supported for carrier-mounted
CSUs.
NOTE: This configuration option is not available if the communication port is configured
for synchronous operation and the clock source is external.
Char Length: 8
Next 7 8 Prev
Communication Port Character Length. Configures the character length (7 or 8 bits) for
the communication port.
NOTES:
– This configuration option must be set to 8 if the communication port is used as the
network communication link.
– This configuration option is not available if the communication port is configured for
synchronous operation.
CParity: None
Next None Even Odd Prev
Communication Port Parity. Configures the parity (none, even, or odd) for the
communication port.
NOTE: This configuration option is not available if the communication port is configured
for synchronous operation.
CStop Bits: 1
Next 1 1.5 2 Prev
Communication Port Stop Bits. Configures the number of stop bits (1, 1.5, or 2) for the
communication port.
NOTE: This configuration option is not available if the communication port is configured
for synchronous operation.
Ignore DTR: No
Next Yes No Prev
Communication Port Ignore DTR State. Specifies whether the CSU ignores the state of
the Data Terminal Ready (DTR) input to the communication port.
Yes
–
DTR is ignored.
No
–
DTR is not ignored.
NOTE: This configuration option is not available if the communication port is configured
for synchronous operation.
Table C-4.
User Interface Configuration Options (6 of 10)
Содержание ACCULINK 3150
Страница 1: ...ACCULINK CSU Models 3150 A4 and 3151 Operator s Guide Document No 3150 A2 GB24 10 March 2001...
Страница 16: ...About This Guide x March 2001 3150 A2 GB24 10...
Страница 28: ...2 Installation 2 8 March 2001 3150 A2 GB24 10...
Страница 40: ...3 Using the Front Panel 3 12 March 2001 3150 A2 GB24 10...
Страница 66: ...4 Configuration 4 26 March 2001 3150 A2 GB24 10...
Страница 74: ...5 Security 5 8 March 2001 3150 A2 GB24 10...
Страница 118: ...8 Testing 8 18 March 2001 3150 A2 GB24 10...
Страница 120: ...A Front Panel Menu A 2 March 2001 3150 A2 GB24 10...
Страница 152: ...C Configuration Options C 30 March 2001 3150 A2 GB24 10...
Страница 168: ...E Pin Assignments E 10 March 2001 3150 A2 GB24 10...
Страница 192: ...F SNMP MIB Objects F 24 March 2001 3150 A2 GB24 10...
Страница 218: ...J Equipment List J 2 March 2001 3150 A2 GB24 10...
Страница 228: ...Glossary GL 10 March 2001 3150 A2 GB24 10...