C. Configuration Options
C-10
March
2001
3150-A2-GB24-10
ComEscapeSeq:
Next Edit Clear Prev
Carrier Communication Port Escape Sequence. Specifies the communication port’s
escape sequence. Once the external device connection has been established, either you
or the CSU can command the external device to disconnect. Before doing so, you may
need to send the escape sequence out to switch the external device into command mode.
The escape sequence is an ASCII text string and may be up to 20 characters in length. If
the escape sequence is NULL, no escape sequence is sent out.
Edit
–
Allows you to edit and/or display the escape sequence using the generic text string
entry screen.
Clear
–
Allows you to clear the escape sequence. The escape sequence is set to a null
string.
NOTES:
– This configuration option is available on carrier-mounted CSUs only.
▲
– This configuration option is not available if the ComExtDev configuration option is
set to AT or the communication port is disabled.
ComEscDel: None
Next None 0.2s 0.4s 0.6s 0.8s 1.0s Prev
Carrier Communication Port Escape Sequence Delay. Specifies the delay used while
sending the communication port escape sequence. Use the communication port escape
delay to specify the delay before sending the first character of the escape sequence and
the delay after the last character of the escape sequence. During the delay, no data is
sent out the communication port.
None
–
No communication port escape sequence delay.
X.Xs
–
The delay used during the communication port escape sequence (where
X.X is
0.2, 0.4, 0.6, 0.8, or 1.0 seconds).
NOTES:
– This configuration option is available on carrier-mounted CSUs only.
▲
– This configuration option is not available if the ComExtDev configuration option is
set to AT or the communication port is disabled.
– ComEscDel must be configured for a delay greater than or equal to the escape
guard time required by the external device.
Table C-4.
User Interface Configuration Options (4 of 10)
Содержание ACCULINK 3150
Страница 1: ...ACCULINK CSU Models 3150 A4 and 3151 Operator s Guide Document No 3150 A2 GB24 10 March 2001...
Страница 16: ...About This Guide x March 2001 3150 A2 GB24 10...
Страница 28: ...2 Installation 2 8 March 2001 3150 A2 GB24 10...
Страница 40: ...3 Using the Front Panel 3 12 March 2001 3150 A2 GB24 10...
Страница 66: ...4 Configuration 4 26 March 2001 3150 A2 GB24 10...
Страница 74: ...5 Security 5 8 March 2001 3150 A2 GB24 10...
Страница 118: ...8 Testing 8 18 March 2001 3150 A2 GB24 10...
Страница 120: ...A Front Panel Menu A 2 March 2001 3150 A2 GB24 10...
Страница 152: ...C Configuration Options C 30 March 2001 3150 A2 GB24 10...
Страница 168: ...E Pin Assignments E 10 March 2001 3150 A2 GB24 10...
Страница 192: ...F SNMP MIB Objects F 24 March 2001 3150 A2 GB24 10...
Страница 218: ...J Equipment List J 2 March 2001 3150 A2 GB24 10...
Страница 228: ...Glossary GL 10 March 2001 3150 A2 GB24 10...