C. Configuration Options
C-8
March
2001
3150-A2-GB24-10
Password: None
Next None Com Modem Both Prev
Password Mode. Activates a password prompt that prevents access until a password is
entered.
None
–
Does not require a password.
Com
–
Prompts the communications port user to enter a password.
Modem
–
Prompts the remote modem port user to enter a password.
Both
–
Prompts both the communications port user and the remote modem port user to
enter a password.
Com Port: Disab
Next Enab Disab Prev
Setting the Carrier Communication Port. Enables the use of the communication port in
carrier-mounted CSUs.
Enab
–
This communication port is enabled.
Disab
–
The communication port is disabled.
NOTE: This configuration option is available on carrier-mounted CSUs only.
▲
Com Use: ASCII
Next Mgmt ASCII Term Prev
Communication Port Use. Specifies how the communication port is used.
Mgmt
–
Configures the communication port as the link to an SNMP or Telnet system.
ASCII
–
Configures the communication port as a proprietary ASCII port supporting Front
Panel Emulation software and ASCII alarm messages. Only one ASCII communication
port is allowed per 3000 Series carrier.
Term
–
Configures the communication port as the interface to an async terminal.
ComExtDev: Disab
Next Disab AT Other Prev
Carrier Communication Port’s External Device Commands. Specifies the communication
port’s external device commands. When this configuration option is disabled, no
commands are sent out the communication port. Select AT to have standard attention
(AT) commands sent out the communication port to control the external device. Select
Other to configure the connect prefix, the connect indication string, the escape sequence,
the escape sequence delay, and the disconnect string.
Disab
–
Allows no commands to be sent out the communication port.
AT
–
Allows standard AT commands to be sent out the communication port.
Other
–
Allows user configurable commands to be sent out the communication port.
NOTES:
– This configuration option is available on carrier-mounted CSUs only.
▲
– This configuration option is not available if the communications port is disabled.
– Carrier Detect (CD) is used to detect that the external device’s connection is lost.
Therefore, do not allow the CD lead to be forced on by the external device.
– The external device should be strapped to ignore Data Terminal Ready (DTR).
Table C-4.
User Interface Configuration Options (2 of 10)
Содержание ACCULINK 3150
Страница 1: ...ACCULINK CSU Models 3150 A4 and 3151 Operator s Guide Document No 3150 A2 GB24 10 March 2001...
Страница 16: ...About This Guide x March 2001 3150 A2 GB24 10...
Страница 28: ...2 Installation 2 8 March 2001 3150 A2 GB24 10...
Страница 40: ...3 Using the Front Panel 3 12 March 2001 3150 A2 GB24 10...
Страница 66: ...4 Configuration 4 26 March 2001 3150 A2 GB24 10...
Страница 74: ...5 Security 5 8 March 2001 3150 A2 GB24 10...
Страница 118: ...8 Testing 8 18 March 2001 3150 A2 GB24 10...
Страница 120: ...A Front Panel Menu A 2 March 2001 3150 A2 GB24 10...
Страница 152: ...C Configuration Options C 30 March 2001 3150 A2 GB24 10...
Страница 168: ...E Pin Assignments E 10 March 2001 3150 A2 GB24 10...
Страница 192: ...F SNMP MIB Objects F 24 March 2001 3150 A2 GB24 10...
Страница 218: ...J Equipment List J 2 March 2001 3150 A2 GB24 10...
Страница 228: ...Glossary GL 10 March 2001 3150 A2 GB24 10...