8. Testing
8-6
March 2001
3150-A2-GB24-10
3. From the Rem Loopback screen, press F1 to select LLBUP (Line Loopback
Up), or press F2 to select LLBDN (Line Loopback Down).
The Line Loopback sequence is sent up or downstream to the far-end CSU for
10 seconds. During this time,
Sending
appears on Line 2 of the LCD,
followed by
Command Complete
when 10 seconds have elapsed.
You can press any function key to restore the Rem Loopback screen without
affecting transmission of the loopback code.
Local Loopback Tests
The Local Loopback tests enable you to conduct circuit testing and fault isolation
for the digital line. The supported local loopback tests are:
Line Loopback (LLB)
Payload Loopback (PLB)
DTE Loopback (DLB)
Repeater Loopback (RLB)
The Line Loopback command can be activated and deactivated in response to
commands received over the network interface. The Network Interface
configuration option NET LLB controls whether the CSU responds to the
commands transmitted on the network interface to initiate LLBs (see
Appendix C,
Configuration Options
).
Local loopback tests can be aborted (Abort Command) at any time.
No more than two local loopbacks can be active at any one time. An additional
restriction prohibits certain loopbacks from running at the same time. Valid
loopback combinations listed in
Table 8-2, Valid Loopback Combinations
, are
identified by YES.
F1
F2
F3
Rem Loopback:
LLBUP LLBDN
Table 8-2.
Valid Loopback Combinations
LLB
PLB
DLB
RLB
LLB
N/A
NO
YES
YES
PLB
NO
N/A
YES
NO
DLB
YES
YES
N/A
NO
RLB
YES
NO
NO
N/A
Содержание ACCULINK 3150
Страница 1: ...ACCULINK CSU Models 3150 A4 and 3151 Operator s Guide Document No 3150 A2 GB24 10 March 2001...
Страница 16: ...About This Guide x March 2001 3150 A2 GB24 10...
Страница 28: ...2 Installation 2 8 March 2001 3150 A2 GB24 10...
Страница 40: ...3 Using the Front Panel 3 12 March 2001 3150 A2 GB24 10...
Страница 66: ...4 Configuration 4 26 March 2001 3150 A2 GB24 10...
Страница 74: ...5 Security 5 8 March 2001 3150 A2 GB24 10...
Страница 118: ...8 Testing 8 18 March 2001 3150 A2 GB24 10...
Страница 120: ...A Front Panel Menu A 2 March 2001 3150 A2 GB24 10...
Страница 152: ...C Configuration Options C 30 March 2001 3150 A2 GB24 10...
Страница 168: ...E Pin Assignments E 10 March 2001 3150 A2 GB24 10...
Страница 192: ...F SNMP MIB Objects F 24 March 2001 3150 A2 GB24 10...
Страница 218: ...J Equipment List J 2 March 2001 3150 A2 GB24 10...
Страница 228: ...Glossary GL 10 March 2001 3150 A2 GB24 10...