/ Installation Guide
32-Zone Wireless Security Systems
DRAFT
Страница 1: ...MG5000 MG5050 Installation Guide 32 Zone Wireless Security Systems DRAFT ...
Страница 2: ......
Страница 3: ... Zones become Entry Delay 2 32 Regular Arming switches to Force Arming 32 Stay Arming switches to Stay Force Arming 32 Sleep Arming switches to Sleep Force Arming 32 Restrict Arming on Battery Failure 32 Restrict Arming on Tamper Failure 32 Restrict Arming on Wireless Supervision Trouble 33 Arm Disarm with VDMP3 33 Timed Auto Arming 33 No Movement Auto Arming 33 Auto Arming Options 33 One Touch Ar...
Страница 4: ...nada Compliance Statement This device complies with FCC Rules Part 15 and with Industry Canada license exempt RSS standard s Operation is subject to two conditions This device may not cause harmful interference This device must accept any interference that may be received or that may cause undesired operation Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils rad...
Страница 5: ...mum number per system K10V H K32 K32LCD K32LX K35 K636 TM50 TM70 10 and 32 Zone Hardwired LED and LCD Keypad Module Touchscreen 15 total including ZX8 ZX82 ZX8 ZX8SP ZX82 8 Zone Expansion Module 3 RPT1 Magellan Wireless Repeater Module 2 VDMP3 Plug In Voice Dialer 1 IP150 IP Internet Module 1 PCS250 PCS250G PCS265LTE Communicator Module 1 RX1 Wireless Receiver Module 1 PGM4 4 Output Expansion Modu...
Страница 6: ... Battery 12 VDC 4 Ah 7Ah Battery charging current 500 mA On board zones MG5000 2 MG5050 5 Bell output 1A fuseless shutdown at 3A On board PGMs MG5000 2 MG5050 4 1 trigger All on board PGMS are 100 mA low current outputs Dimensions MG5000 14 x 10 4 cm 5 5 x 4 1 in MG5050 19 x 10 2 cm 7 5 x 4 in Weight 18g Operating temperature 0 C to 50 C 32 F to 122 F Humidity 5 90 Standards TBD Cannot exceed 200 ...
Страница 7: ...st be grounded to the cold water pipe AC Power Do not use any switch controlled outlets to power the transformer in order to avoid accidental user AC shut off Connect the transformer as shown in Figure 1 Use the below table for appropriate transformer Use only a safety approved transformer with rated output voltage of 16 5 Vac and rated power of 40 VA maximum Backup Battery To provide power during...
Страница 8: ...gle conductor solid copper wire 12 Ground clamp 13 Cold water pipe grounding 14 To ground 15 Keypad zone configuration 16 Zone connection if EOL is enabled see section 706 option 2 on page page 28 17 To connect additional wiring to auxiliary power use the red and black keypad connectors auxiliary power will shut down if current exceeds 3A if the auxiliary output is overloaded and shuts down you mu...
Страница 9: ...gle conductor solid copper wire 12 Ground clamp 13 Cold water pipe grounding 14 To ground 15 Keypad zone configuration 16 Zone connection if EOL is enabled see section 706 option 2 on page page 28 17 To connect additional wiring to auxiliary power use the red and black keypad connectors auxiliary power will shut down if current exceeds 3A if the auxiliary output is overloaded and shuts down you mu...
Страница 10: ...t Paradox Distributor Support For UL recommended installation for the MG5000 only place the PCB one notch lower than the mounting location MG5000 8x10 MG5000 11x11 MG5050 11x11 For EN compliancy use the Tamper Kit TK278 Insert into one of the designated slots on the metal box and wire to an input Secure screw to wall Tamper Kit Slot Tamper Kit Slot Tamper Kit TK278 ...
Страница 11: ...lls sirens and other warning devices requiring a steady voltage output during an alarm The bell output supplies 12Vdc upon alarm and can support one 30 watt or two 20 watt sirens The bell output uses a fuseless circuit and will automatically shut down if the current exceeds 3A When this occurs the Maximum Bell Current failure will only appear in the keypad s trouble display see Trouble Display on ...
Страница 12: ... motion detectors and door contacts are connected to the control panel s zone input terminals Figure 3 demonstrates single zone input terminal connections recognized by the panel Once connected the associated zone s parameters must be defined Figure 3 Single Zone Input Connections ...
Страница 13: ... is a software oriented feature that enables two detection devices to be installed per hardwired input terminal Each detection device has its own zone displays its zone status on the keypad and sends its own alarm codes Fire zones cannot be doubled Figure 4 Advanced Technology Zone Connections ...
Страница 14: ...ction 866 Figure 5 Fire Circuits 4 Wire and 2 Wire Installation For 4 wire installation program the Activation Event so that the smoke detectors can be reset by pressing the CLEAR ENTER keys for three seconds See Event Group 6 in the Event Description list in the programming guide For 2 wire smoke detector installation connect the 2 wire smoke detectors If a line short occurs or the smoke detector...
Страница 15: ... sections eight options will be displayed where each option from 1 to 8 represents a specific feature Press the key corresponding to the desired option This means the option is ON Press the key again to remove the digit thereby turning OFF the option When the options are set press the ENTER key to save and advance to the next section Data Display Mode except K32LCD In the Data Display Mode you can...
Страница 16: ...ad Press ENTER Enter your INSTALLER CODE default 0000 000000 or MAINTENANCE CODE empty by default Press and hold for three seconds Enter the desired zone number key K32 K32LCD 2 digit entry 01 to 32 K10V H 1 digit entry 1 to 0 10 Press ENTER to save and exit programming mode Press CLEAR to erase data without saving Press CLEAR CLEAR to exit programming mode without saving ...
Страница 17: ...lete arm Delete whole entry off Toggle numeric alphanumeric keys byp Toggle lower case upper case mem Special characters Label Sections 181 to 212 32 Zone Labels 341 to 356 16 PGM Labels 511 to 542 32 User Labels 771 to 772 2 Partition Labels 568 to 569 2 Wireless Labels 599 to 606 8 Wireless Keypads 781 to 795 15 Bus Modules Labels Polish 001 002 003 004 005 006 007 Hungarian 001 002 003 Turkish ...
Страница 18: ...ress key once Press key twice Press key three times 1 A B G 2 D E Z 3 H Q I 4 K L M 5 N O 6 P R S 7 T U F 8 C Y W Greek Special Characters Catalogue 016 032 048 064 080 096 112 128 144 160 176 192 208 224 240 017 033 049 065 081 097 113 129 145 161 177 193 209 225 241 018 034 050 066 082 098 114 130 146 162 178 194 210 226 242 019 035 051 067 083 099 115 131 147 163 179 195 211 227 243 020 036 052...
Страница 19: ...MG5000 MG5050 Installation Guide 19 Russian Special Characters Catalogue Russian Keypad Letter Assignment ...
Страница 20: ... 123456 The Installer Code can be used to program the System Master Code With the System Master Code a user can use any arming method and can program any user access code but not the User Code Options The System Master Code can be 4 or 6 digits in length where each digit can be any digit from 0 to 9 The System Master Code can be modified but cannot be erased To change the System Master Code press ...
Страница 21: ...e other User Code Options selected Please note that with the Arm Only option the user can cancel a recently armed system by re entering the access code before the end of the exit delay PGM Activation Sections 404 to 432 User Codes 004 to 048 Option 7 OFF User Code follows User Code Options and can activate a PGM default Option 7 ON User Code can activate a PGM only With option 7 off entering the a...
Страница 22: ...alidate your path and once for the non path zone If you do not validate the non path zone the system will fall in alarm Entry Exit with a Keypad When entering with a keypad the path zones will fall into entry delay allowing you to reach the keypad Use the keypad to disarm the system and switch to Stay arm mode When exiting with a keypad only the path zones will fall into delay same as exit delay a...
Страница 23: ...int requires a longer delay than the other entry point or in a partitioned system where each partition may require a different entry delay Entry Delay 2 Zones Sections 001 to 032 Zones 1 to 32 First Digits 02 Entry Delay 2 zones are identical to the Entry Delay 1 zones except it uses a separate entry delay timer To program the Entry Delay 2 Timer key in the desired 3 digit delay value 000 to 255 s...
Страница 24: ...e zone is bypassed by the system See Zone Definition Status on page 26 for any exceptions Follow Full Arm Zones Sections 001 to 032 Zones 1 to 32 First Digits 07 Upon regular arming the zone is Follow see Follow Zones on page 24 Upon Stay or Sleep arming the zone is bypassed by the system See Zone Definition Status on page 26 for any exceptions Instant Zones Sections 001 to 032 Zones 1 to 32 First...
Страница 25: ...ry Zones Sections 001 to 032 Zones 1 to 32 First Digits 16 When a 24Hr Burglary Zone opens whether the system is armed or disarmed the control panel will immediately generate an alarm This alarm is defined by the alarm type configured in Zone Programming under zone options 4 and 5 See Alarm Types on page 27 24 Hr Hold up Zones Sections 001 to 032 Zones 1 to 32 First Digits 17 When a 24Hr Hold up z...
Страница 26: ...ges depending on the arm status and if the Flex Instant delay is enabled see Zone Definition Status on page 26 Zone Partition Assignment Sections 001 to 032 Zones 1 to 32 The control panel provides the option of partitioning the security system into two completely independent systems Sections 001 to 032 represent zones 1 through 32 respectively where the third digit in each of these sections repre...
Страница 27: ...rm report code and provides a pulsed output see Figure 8 on page 24 for any bells or sirens connected to the control panel s bell output 4 ON 5 OFF Silent Alarm When the conditions for an alarm are met the control panel can transmit the appropriate Zone Alarm report code and will not activate the control panel s bell output The appropriate ARM or STATUS LED on the keypads will flash to indicate an...
Страница 28: ...e first zone on the ZX8 ZX82 ID A Panel 1 a tamper input By default it is a zone Tamper Input on ZX8 ZX82 ID B Panel 9 Section 706 General Zone Options 2 Option 5 OFF Zone B default Option 5 ON Tamper input Enabling this option will make the first zone on the ZX8 ZX82 ID B Panel 9 a tamper input By default it is a zone Tamper Input on ZX8 ZX82 ID C Panel 17 Section 706 General Zone Options 2 Optio...
Страница 29: ...s then turn it to the OFF position Keyswitch Options Each keyswitch zone can be programmed with one or more options Stay Sleep Disarm Option Keyswitch On board hardwire control panel zones only Option 4 When enabled the keyswitch can only disarm assigned Stay or Sleep armed partitions When option 4 is disabled the keyswitch can disarm partitions armed using any arming method Arm Only Keyswitch On ...
Страница 30: ...rs within 80 minutes If the control panel does not receive a signal from one of its wireless transmitters within the period of time defined here it can then generate a trouble an alarm and or can transmit a report code to the monitoring station see Supervision Options on page 30 RF Jamming Supervision Section 700 Zone Options Option 5 OFF RF Jamming Supervision Disabled Option 5 ON RF Jamming Supe...
Страница 31: ... default 3 Enter the desired SECTION NUMBER from sections 610 to 642 4 Enter the HEXADECIMAL VALUE 0 to F of the desired button option from table 2 on page 31 in the appropriate space If you do not wish to program a button combination press the SLEEP key to skip Table 2 Button Options 0 Button Disabled 8 Generate a Panic 1 Alarm 1 Regular Regular Force arming 9 Generate a Panic 2 Alarm 2 Stay Stay...
Страница 32: ...ns Option 2 OFF Stay Arming Switches to Stay Force Arming Disabled Option 2 ON Stay Arming Switches to Stay Force Arming Enabled default With this feature enabled the control panel will always Stay Force arm if a force enabled zone is open see Force Zones on page 28 instead of Stay arm when a valid user access code with the Force Arming Option is entered Sleep Arming switches to Sleep Force Arming...
Страница 33: ...in 18 15 into section 762 Auto Arm Timer Section 761 Partition 1 762 Partition 2 Select the section corresponding to the desired partition and program the time use the 24 hour clock e g 6 30PM 18 30 that you wish the control panel to attempt to arm the selected partition and or send the Late to Close report code No Movement Auto Arming Section 741 Partition 1 742 Partition 2 Option 2 OFF No Moveme...
Страница 34: ...wice upon disarming via the keypad Bell Squawk On Arm Disarm with Remote Control Section 704 Arming Disarming Options Option 4 OFF Bell Squawk on Arm Disarm with Remote Control Disabled default Option 4 ON Bell Squawk on Arm Disarm with Remote Control Enabled When this feature is enabled the bell or siren will squawk once upon arming with a remote control and twice upon disarming with a remote con...
Страница 35: ... their presence and functionality If a device has not sent a signal within that time period the control panel can generate a trouble an alarm and or transmit a report code to the monitoring station The system will react to an RF zone and a keypad bus module differently Tamper Bypass Options Section 705 Zone Options Option 5 OFF Tampers on bypassed zones will be ignored Option 5 ON Will generate a ...
Страница 36: ...Silent default Option 6 ON Panic 3 is Audible Silent alarm The control panel emits a confirmation beep and transmits the appropriate Panic report code if programmed in section 863 The control panel will not enable the keypad buzzers or the control panel s BELL output no audible alarm Audible alarm Same as silent alarm except the keypad buzzers and the BELL output will activate until a user cancels...
Страница 37: ...d for the programmed amount of time in the partition Partial Arming A partition was Stay Sleep or Force armed or armed with Bypassed zones Section 861 Quick Arming A partition was armed using a One touch arming feature Arming via PC A partition was armed using the BabyWare software N A N A Special Disarming Report Codes Section 862 When using one of the special disarming features the control panel...
Страница 38: ...ow recommended limits Wireless Zone Low Battery The battery voltage of a wireless transmitter has dropped below recommended limits Wireless Zone Supervision Lost The control panel has lost communication with a wireless zone Section 869 Wireless PGM Supervision Lost The control panel has lost communication with a wireless PGM Wireless PGM Tamper The anti tamper switch of a wireless PGM has been tri...
Страница 39: ...any digit from 0 to 9 and any special keys or functions up to a maximum of 32 digits After the maximum dialing attempts see Maximum Dialing Attempts on page 41 to one monitoring station telephone number have failed the control panel will then dial the backup telephone number If the Alternate Dial Option see Alternate Dial Option on page 41 is enabled the control panel will dial the programmed back...
Страница 40: ...rogrammed using the Ademco Contact ID Report Codes in the programming guide Event Call Direction Section 802 Options 1 to 3 Arming Disarming Option 1 ON Call MSTN 1 Option 2 ON Call MSTN 2 Option 3 ON Call Pager telephone number Section 802 Options 5 to 7 Alarm Alarm Restore Option 5 ON Call MSTN 1 Option 6 ON Call MSTN 2 Option 7 ON Call Pager telephone number Section 803 Options 1 to 3 Tamper Ta...
Страница 41: ...l the same monitoring station telephone number before proceeding to the next number Maximum Dialing Attempts VDMP3 Section 841 000 to 255 attempts Default 8 attempts The value programmed in section 841 determines how many times the control panel will re dial the same telephone number before proceeding to the next number The maximum dialing attempts programmed in this section is independent from th...
Страница 42: ...ation Example The Closing Delinquency Timer for partition 1 in section 719 is programmed for 005 days The control panel verifies when partition 1 was last disarmed at midnight every day If partition 1 was not armed within the last 5 days the panel will transmit a Closing Delinquency event to the monitoring station The Closing Delinquency Event and timer apply only to partition 1 Power Failure Repo...
Страница 43: ... zone or silent panic alarm to switch to audible TLM Fail Timer Section 830 016 to 255 x 2 seconds Default 32 seconds If TLM does not detect the existence of a telephone line for the duration of this period the control panel will generate the condition s defined by the TLM options Pager Reporting Delay Section 834 Communication Timers 000 to 255 seconds Default 20 seconds When using the Pager Repo...
Страница 44: ...e deactivate when the programmed PGM Deactivation Event occurs Instead of deactivating the PGM when a specific event occurs the PGM can deactivate after a programmed period elapses see PGM Delay on page 44 For the Event List see the Programming Guide If using the PGM Delay these sections can be used as a second activation event 1 Enter section that represents the desired PGM PGM1 221 PGM2 223 etc ...
Страница 45: ...gramming Sections 301 to 316 The programming of the PGMs is accomplished in two steps 1 Assign the PGMs to the panel 2 Program the PGMs PGM Programming can be executed through the Installer Quick Menu in the programming guide How Do I Assign PGMs to the Panel 1 Press the ENTER key 2 Enter your INSTALLER CODE default 0000 000000 or MAINTENANCE CODE empty by default 3 Enter the desired SECTION NUMBE...
Страница 46: ...and Partition 2 Partitioning can be used in installations where shared security systems are more practical such as an office warehouse building When partitioned each zone each user code see Access Codes on page 20 and some of the system s features can be assigned to Partition 1 Partition 2 or both If the system is not partitioned all user codes and features will be recognized as belonging to Parti...
Страница 47: ... can also set a customized DST Set section 732 for the DST starting period and 733 for the DST ending period Both sections recognize 5 different entries of 2 digits each All entries must be assigned in this respective order Audible Trouble Warning Except AC Failure Section 700 General System Options Option 3 OFF Audible trouble warning except AC failure default Option 3 ON Audible trouble warning ...
Страница 48: ...option is enabled the panel will display entry delays on the K32LCD keypad modules Display Exit Delay on LCD keypad K32LCD Section 701 General System Options Option 8 OFF Display exit delay on LCD keypad Option 8 ON Display exit delay on LCD keypad default When this option is enabled the panel will display exit delays on the K32LCD keypad modules ...
Страница 49: ...swer the call This section applies to the Plug in Voice Dialer when using a VDMP3 Panel Identifier Section 910 0000 to FFFF This 4 digit code identifies the control panel to the BabyWare software before initiating communication The control panel will verify that the Panel Identifier in the BabyWare software is the same If the codes do not match the control panel will not establish communication Th...
Страница 50: ... capacity before attempting to re communicate with the monitoring station When the Event Buffer is full each subsequent new event will erase the oldest event in the buffer Call Back BabyWare Section 900 Dialer Options Option 1 OFF Call Back BabyWare Disabled default Option 1 ON Call Back BabyWare Enabled For additional security when a PC using the BabyWare software attempts to communicate with the...
Страница 51: ...rol panel 2 AC failure on control panel 3 Auxiliary overload on control panel 4 Wireless keypad AC failure 5 Wireless keypad battery failure 6 Wireless repeater AC failure 7 Wireless repeater battery failure 3 Bell trouble 1 Bell disconnect on control panel 2 Bell overload on control panel 4 Communication trouble 1 Telephone Line Monitoring on control panel 2 Fail to communicate on Monitoring Tele...
Страница 52: ...4 Bell Output Connection 9 Disconnected Report Code 37 Overload Report Code 37 Bell Squawk On Arm Disarm With Keypad 33 With Remote Control 33 Bypassable Zones 26 C Call Back Feature 49 Cancel Auto Arm Report Code 36 Charge Current 45 Closing Delinquency 41 Cold Start Report Code 37 Configuring The LED Keypads 15 Connecting Bells or Sirens 9 Fire Zones 13 PGMs 10 Single Zone Inputs 11 Telephone Li...
Страница 53: ...On Battery Fail 31 On Tamper Trouble 31 32 No Audible Feedback Upon Stay Arming 33 No Exit Delay When Arming with Remote Control 33 No Movement Auto Arming 32 No Movement Report Code 36 Number of Rings 48 Numbers 40 O One Touch Arming 33 Report Code 36 Options Alarm 34 Arming and Disarming 31 Auto Arming 32 User code 19 Zone 25 Override Answering Machine 48 P Pager 42 Panel Answer Options 48 Panel...
Страница 54: ...Upload Download 14 Special Alarm Report Codes 36 Special Arming Report Codes 36 Special Disarming Report Codes 36 Special Reporting Codes 37 Specifications 6 Standard Pulse Formats 39 StayD 21 Switch 40 Switch to Stay Arming 31 System 41 Master Code 19 Settings 45 Trouble Report Codes 37 Trouble Restore Codes 36 37 T Tamper Bypass Options 34 Tamper Recognition 34 Telephone Line Connection 9 Teleph...
Страница 55: ...pe this product performs to your complete satisfaction Should you have any questions or comments please contact us at support paradox com Additional information can be found on our website www paradox com support Printed in Canada 12 2021 PARADOX COM MG5000 MG5050 EI00 DRAFT ...