6
/ Installation Guide
Specifications
All control panel outputs are rated to operate between 10.8Vdc and 12.1 Vdc
/
Power rating
16.5 VAC (50 or 60Hz) minimum 20 VA (40 VA recommended)
Power consumption
:
1.2A(Max.), 85 mA (Idle)
:
1.2A(Max.), 95 mA (Idle)
Aux. power *
0.7A typical, 0.8A maximum, active shutdown at 1.1A
Battery
12 VDC, 4 Ah/7Ah
Battery charging current
500 mA
On-board zones
:
2
: 5
Bell output **
1A (fuseless shutdown at 3A)
On-board PGMs
:
2
:
4 (1+/- trigger)
All on-board PGMS are 100 mA low-current outputs
Dimensions
:
14 x 10.4 cm (5.5 x 4.1 in.)
:
19 x 10.2 cm (7.5 x 4 in.)
Weight
18g
Operating temperature
0°C to 50°C (32°F to 122°F)
Humidity
5% - 90%
Standards
TBD
* Cannot exceed 200 mA for UL installations
** Cannot exceed 1A for UL installations
30 hrs backup
60 hrs backup
Recharge to 80% (@350 mA)
7 AHr
150 mA
50 mA
20 hrs.