/ Installation Guide
5
Introduction
Features
•
32 zones (any of which can be wireless or keypad zones)
•
32 users and 32 remote controls (one per user)
•
In-field upgradeable
•
Menu-driven programming for the Installer, Master, and Maintenance codes. This enables you to program the panel through a simple and easy to use
interface, without the use of section numbers
•
Multiple telephone numbers for event reporting: Three for the monitoring station, five for personal dialing
•
Calendar with daylight savings time
•
Sleep arming method: Similar to Stay arming, Sleep arming allows users to remain in a protected area, but provides a higher level of protection
•
Connect up to 15 hardwired keypads on the 4-wire communication bus
•
Push button power reset
•
Available in 433MHz or 868MHz
•
RF jamming supervision (section
[700]
, option [5]): The control panel will report a trouble if the RF signal is being jammed
•
Supports SIA reporting format to central station (V4.86 and lower)
Requirements
•
PCS265 LTE V4.37 and higher
•
IP150+ V5.45 and higher
System Overview
Modules Current Consumption List
Module
Description
Maximum number per system
K10V/H, K32+,, K32LX, K35, K636,
TM50, TM70
10 and 32-Zone Hardwired LED and LCD Keypad Module,
Touchscreen
15 total including ZX8 / ZX82
ZX8, ZX8SP, ZX82
8-Zone Expansion Module
3
RPT1
Magellan Wireless Repeater Module
2
VDMP3 Plug-In
Voice
Dialer
1
IP150+
IP Internet Module
1
PCS250/PCS250G, PCS265LTE
Communicator Module
1
RX1
Wireless Receiver Module
1
PGM4
4-Output Expansion Module
1
PGM82
8-Output Expansion Module
1
HUB2
2-Port HUB and Bus Isolator
1
PS25/PS45
Power supply
1
HD78F/HD88
IP Camera / Detector
15
Module
Current Consumption
Module
Current Consumption
K10V/H
Min. = 44 mA / Max. = 72 mA
RPT1
65 mA
K32+
Min. = 49 mA / Max. = 148 mA
VDMP3
Min. = 28 mA / Max. = 28 mA
Min. = 43 mA / Max. = 86 mA
IP150+
100 mA
K32LX
120 mA
PCS250
Standby:100 mA / Alarm: 450 mA
K35
Min. = 30 mA / Max. = 70 mA
PCS250G
Standby:100 mA / Alarm: 450 mA
K636
Min. = 15 mA / Max. = 30 mA
PCS265LTE
Standby: 60 mA / Max. = 300 mA
TM50
150 mA max + 80 mA sounder
RX1
25 mA
TM70
250 mA max + 80 mA sounder
PGM4
Min. = 13 mA / Max. = 150 mA
ZX8
Min. = 29 mA / Max. = 31 mA
PGM82
315 mA (all PGMs activated)
ZX8SP
28 mA
HUB2
Min. = 24 mA / Max. = 50 mA
ZX82
95 mA max (all LED on)
HD88
350 mA - IR illumination ON
250 mA - IR illumination OFF
100 mA - System lost AC / Battery operation
HD78F
350 mA - IR illumination ON
250 mA - IR illumination OFF
100 mA - System lost AC / Battery operation