/ Installation Guide
41
Example:
The system is armed and zone 1 has been breached causing an alarm. If options
[5]
and
[7]
are OFF and option
[6]
is ON in section
[802]
, the control panel
will attempt to communicate with MSTN 2.
Account Numbers
Section
[811]
: Partition 1, Section
[812]
: Partition 2
All report codes are preceded by a 4-digit or 3-digit Partition Account Number to ensure correct identification in a partitioned system. Partition account numbers
can be any hexa-digit from 1 to F. To enter a 3-digit account number, simply press the
[
SLEEP
]
key followed by a 3-digit account number. Also, when using 3-digit
account numbers, you must use 1-digit report codes.
Dialing Method
Section
[800]
: Dialer Options
Option
[6]
OFF= Pulse Dialing (see “Pulse Ratio” on page 41).
Option
[6]
ON= Tone/DTMF Dialing (default)
Pulse Ratio
Section
[800]
: Dialer Options
Option
[7]
OFF= European Pulse Ratio of 1:2
Option
[7]
ON= U.S.A. Pulse Ratio of 1:1.5 (default)
When using Pulse dialing, you can select one of two Pulse Ratios. Although most European countries use the 1:2 pulse ratio, the 1:1.5 ratio may provide better results
in some cases. The same applies for North American countries. If the 1:1.5 pulse ratio is not providing the desired results, the 1:2 ratio may be used.
Maximum Dialing Attempts
Section
[831]
000 to 255 attempts, Default = 8 attempts
The value programmed in section
[081]
determines how many times the control panel will re-dial the same monitoring station telephone number before
proceeding to the next number.
Maximum Dialing Attempts - VDMP3
Section
[841]
000 to 255 attempts, Default = 8 attempts
The value programmed in section
[841]
determines how many times the control panel will re-dial the same telephone number before proceeding to the next
number. The maximum dialing attempts programmed in this section is independent from those programmed in section
[831]
of the panel dialer used for
monitoring station reporting.
Delay Between Dialing Attempts
Section
[832]
000 to 255 seconds, Default = 20 seconds
This delay determines the amount of time the control panel will wait between each dialing attempt.
This section applies to the Plug-in Voice Dialer when using
a VDMP3.
Switch to Pulse on 5th Attempt
Section
[800]
Option
[3]
OFF=
Switch to Pulse on 5th Attempt Disabled (default)
Option
[3]
ON=
Switch to Pulse on 5th Attempt Enabled
With option
[3]
ON, the control panel will switch to pulse dialing on the 5th attempt of reaching the monitoring station.
Alternate Dial Option
Section
[800]
: Dialer Options
Option
[4]
OFF= Alternate Dial Disabled (default)
Option
[4]
ON= Alternate Dial Enabled
With option
[4]
OFF, the control panel will dial the backup programmed in section
[817]
after all attempts to one monitoring station number have failed. With
option
[4]
ON, the control panel will dial the backup number after every failed attempt.
Force Dial Option
Section
[800]
: Dialer Options
Option
[5]
OFF= Force Dial Disabled
Option
[5]
ON= Force Dial Enabled (default)
With option
[5]
is enabled, the panel will dial a telephone number even if no dial tone is present after 4 seconds.