4 RU SSPA Chassis Operations Manual
201627 REV X
91
Note: In general, data length must be at least two (2) bytes to form an
integer; the lower byte must come first. If an odd number of bytes arrived,
the last data byte in the packet will be saved as the lower part of the
integer; the upper part will be 0 by default.
Table 7-7: System Threshold Addressing Details (Read Only)
Data
Address
Min. Data
Length
(bytes)
Description
Limits and valid values
1
2
Forward RF power
If RF Units (Table 7.6, Data Address 20)
= 0, then 0.1 dBm per 1 value; If RF
Units = 1, then 0.1 Watt per 1 value
(Version 3.40*)
2
2
Reflected RF power
If RF Units (Table 7.6, Data Address 20)
= 0, then 0.1 dBm per 1 value; If RF
Units = 1, then 0.1 Watt per 1 value
(Version 3.40*)
3
2
SSPA DC Current
0.2A per 1 value; Value will return (-100)
if reading is not available at this time.
4
2
Main Power Supply 1
Output Voltage
0.1V per 1 value; Value will return (-100)
if reading is not available at this time.
5 2
Main Power Supply 2
Output Voltage
0.1V per 1 value; Value will return (-100)
if reading is not available at this time.
6
2
Booster Power Supply 1
Output Voltage
0.1V per 1 value; Value will return (-100)
if reading is not available at this time.
7 2
Booster Power Supply 2
Output Voltage
0.1V per 1 value; Value will return (-100)
if reading is not available at this time.
8
2
SSPA Core Temperature
1°C per 1 value; Value will return (-100)
if reading is not available at this time.
* Version numbers listed indicate the version in which the listed feature was introduced.
12
2
Cabinet Temperature
1°C per 1 value; Value will return (-100)
if reading is not available at this time.
Version 4.40*.
11
2
N+1 System Reflected Power
(available from Master unit
only!)
If RF Units (
Table 7-6
, Data Address 20)
= 0, then 0.1 dBm per 1 value; If RF
Units = 1, then 1 Watt per 1 Value. Value
will return (-100) if reading is not avail-
able at this time. Version 4.20*.
9
2
N+1 System Forward Power
(available from Master unit
only!)
If RF Units (
Table 7-6
, Data Address 20)
= 0, then 0.1 dBm per 1 value; If RF
Units = 1, then 1 Watt per 1 Value. Value
will return (-100) if reading is not avail-
able at this time. Version 4.20*.
10
2
N+1 Estimated System Gain
(available from Master unit
only!)
0.1dB per Value. Estimated N+1 system
linear gain. Version 4.20*.
Содержание 4 RU Chassis
Страница 14: ...14 201627 REV X 4 RU SSPA Chassis Operations Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 46: ...46 201627 REV X 4 RU SSPA Chassis Operations Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 78: ...78 201627 REV X 4 RU SSPA Chassis Operations Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 114: ...114 201627 REV X 4 RU SSPA Chassis Operations Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 118: ...118 201627 REV X 4 RU SSPA Chassis Operations Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 126: ...126 201627 REV X 4 RU SSPA Chassis Operations Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 130: ...130 201627 REV X 4 RU SSPA Chassis Operations Manual THIS PAGE LEFT INTENTIONALLY BLANK ...