110
201627 REV X
4 RU SSPA Chassis Operations Manual
Table 7-13: Detailed Conditions
conditionIndex/
conditionValue
conditionTextValue
Value OID
Description
1/INTEGER SummaryFault'NoFault=0,Fault=1
1.3.6.1.4.1.20712.2.1.3.1.2.1 Summary
fault
state
2/INTEGER
PowerSupplyFault'NoFault=0,Fault=1
1.3.6.1.4.1.20712.2.1.3.1.2.2
Power supply fault state
3/INTEGER
HighTemperatureFault'No-
Fault=0,Fault=1
1.3.6.1.4.1.20712.2.1.3.1.2.3 High
Temperature fault state
4/INTEGER
LowRegulatorVoltageFault'NoFault=0,
Fault=1
1.3.6.1.4.1.20712.2.1.3.1.2.4
Low Regulator voltage state
5/INTEGER LowDCCurrentFault'NoFault=0,Fault=1 1.3.6.1.4.1.20712.2.1.3.1.2.5 Low
DC Current fault state
6/INTEGER
AuxiliaryFault'NoFault=0,Fault=1,N/A=2 1.3.6.1.4.1.20712.2.1.3.1.2.6
Auxiliary fault state
7/INTEGER BUCFault'NoFault=0,Fault=1,N/A=2 1.3.6.1.4.1.20712.2.1.3.1.2.7 BUC fault state
8/INTEGER
Module1Fault'NoFault=0,Fault=1,N/A=2 1.3.6.1.4.1.20712.2.1.3.1.2.8
Module1 summary fault state
9/INTEGER Module2Fault'NoFault=0,Fault=1,N/A=2
1.3.6.1.4.1.20712.2.1.3.1.2.9
Module2 summary fault state
10/INTEGER
Module3Fault'NoFault=0,Fault=1,N/A=2 1.3.6.1.4.1.20712.2.1.3.1.2.10 Module3 summary fault state
11/INTEGER Module4Fault'NoFault=0,Fault=1,N/A=2 1.3.6.1.4.1.20712.2.1.3.1.2.11 Module4 summary fault state
12/INTEGER
CollingFanFault'NoFault=0,Fault=1,N/
A=2
1.3.6.1.4.1.20712.2.1.3.1.2.12 Cooling fan fault state
13/INTEGER
LowForwardRFFault'NoFault=0,Fault=1,
N/A=2
1.3.6.1.4.1.20712.2.1.3.1.2.13 Low forward RF fault state
14/INTEGER
HighReflectedRFFault'No-
Fault=0,Fault=1,N/A=2
1.3.6.1.4.1.20712.2.1.3.1.2.14 High reflected RF fault state
15/INTEGER
RFSwitch1Position'Fault=1,N/
A=2,Pos1=3,Pos2=4
1.3.6.1.4.1.20712.2.1.3.1.2.15 PF switch position1 /fault state
16/INTEGER
RFSwitch2Position'Fault=1,N/
A=2,Pos1=3,Pos2=4
1.3.6.1.4.1.20712.2.1.3.1.2.16 PF switch position1 /fault state
17/INTEGER FaultsPortbyte1'0..255
1.3.6.1.4.1.20712.2.1.3.1.2.17 Faults
on logic port 1 raw data
18/INTEGER
FaultsPortbyte2'0..255
1.3.6.1.4.1.20712.2.1.3.1.2.18 Faults on logic port2 raw data
19/INTEGER IOBoardHardwareID'0..255
1.3.6.1.4.1.20712.2.1.3.1.2.19 I/O
Board hardware revision
20/INTEGER
DigitalCoreBoardID'0..255
1.3.6.1.4.1.20712.2.1.3.1.2.20 Digital Core board hardware revision
21/INTEGER UnitStandbyState'Online=1,Standby=0 1.3.6.1.4.1.20712.2.1.3.1.2.21 Current unit redundancy state
22/INTEGER
Reserved’0..255
1.3.6.1.4.1.20712.2.1.3.1.2.22 Reserved for factory use only
23/INTEGER N1UnitState’Slave=0,Master=1,N1Off=2 1.3.6.1.4.1.20712.2.1.3.1.2.23 Unit N+1 state
24/INTEGER
ExtFanFault’NoFault=0,Fault=1,N/A=2
1.3.6.1.4.1.20712.2.1.3.1.2.24 N+1 Cabinet Impeller Fault
25/INTEGER N1SysFaults’0..16
1.3.6.1.4.1.20712.2.1.3.1.2.25 Amount of SSPA faults in N+1 system
26/INTEGER
SelectedAtten(dBx10)’0,,200
1.3.6.1.4.1.20712.2.1.3.1.2.26 Actual SSPA attenuator value
27/INTEGER Reserved’0..255
1.3.6.1.4.1.20712.2.1.3.1.2.27 Reserved for factory use only
28/INTEGER
Reserved’0..255
1.3.6.1.4.1.20712.2.1.3.1.2.28 Reserved for factory use only
Содержание 4 RU Chassis
Страница 14: ...14 201627 REV X 4 RU SSPA Chassis Operations Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 46: ...46 201627 REV X 4 RU SSPA Chassis Operations Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 78: ...78 201627 REV X 4 RU SSPA Chassis Operations Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 114: ...114 201627 REV X 4 RU SSPA Chassis Operations Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 118: ...118 201627 REV X 4 RU SSPA Chassis Operations Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 126: ...126 201627 REV X 4 RU SSPA Chassis Operations Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 130: ...130 201627 REV X 4 RU SSPA Chassis Operations Manual THIS PAGE LEFT INTENTIONALLY BLANK ...