60
12
Troubleshooting
12.1
Identifying faults
Malfunctions and faults can become noticeable in different ways:
n
Nutrunner is not working for no apparent reason:
First note the list of typical errors and issues
.
n
Nutrunner, battery or accessory is faulty or shows signs of
damage.
Contact
Ä
“
PAOLI
service” on page 4
.
Below is a summary of typical malfunctions, issues and answers.
This is intended to provide rapid assistance. For problems that
cannot be solved in this way, contact
Ä
“
PAOLI
service”
on page 4
.
Fault symptom
Measure
The nutrunner will not start.
Check the battery charge status and charge or
replace the battery in the event of insufficient
charge.
The device gets hot too quickly.
Are the openings for the air supply dirty or clogged?
Clean with a soft cloth.
Battery charge status indicator is flashing red.
The battery is not operational. Bring the battery to
within the operating temperature range and then
charge it.
Battery charge status indicator lights up red continu-
ously.
The battery is empty. Charge the battery.
Two brief acoustic signals during use.
The bolting process was not successful. The set
torque was not reached. Determine the bolting
process. Repeat tightening.