Before you begin
30
WARNING!
Danger of injury due to incorrect bracing, over-
loading, breakage!
Incorrect bracing or overloading of the nutrunner or
individual components can result in serious inju-
ries.
– Do not use the nutrunner if the bolting process
is not entirely clear.
– Note the torque chart.
– Check the reaction arm for visible damage prior
to use. Do not use the reaction arm if it is dam-
aged.
– Brace the reaction arm correctly
.
– Do not operate the nutrunner in continuous
ope-ration and do not use it as a drive unit.
– Use only
PAOLI
original parts.
The reaction arms are designed for a maximum
permissible load.
Observe the stickers on the reaction arm and data
sheet.
WARNING!
Danger of crushing when bracing and due to
high weight!
During operation, very strong forces act on the
nutrunner, reaction arm, bracing surface and bolts.
There is a danger of crushing between the reaction
arm and bracing surface during tightening and
loosening. The high weight of the nutrunner can
cause crushing if it falls down.
– Handle the nutrunner with care and as intended.
– Give due consideration to the weight during
transport and during all work.
– Have work performed only by persons who are
physically capable of using the nutrunner safely
despite its high weight.
– Do not reach between the reaction arm and
bracing surface.
– Secure the nutrunner against falling when
working at height.
– Wear safety shoes.
– Also wear an industrial safety helmet for over-
head work.
Incorrect bracing and overloading
Reaction arm
Crushing