6.
Standard direction of rotation: Right-hand
thread
To tighten in counterclockwise direction (CCW), push the
direction of rotation lever (Fig. 23/2) to the left.
ð
An acoustic signal sounds if torque levels are blocked.
7.
NOTICE!
Property damage due to overloading!
In order to loosen bolted connections, it is often the case that
greater torques are needed than those required for bolting.
To set the maximum torque, set the setting level to the break-
away torque level Ensure that all components are
designed for this
load.
Do not use the breakaway torque level for bolting.
In delivery state, the breakaway torque level
is blocked when tightening in clockwise direc-
tion (CW).
8.
NOTICE!
Property damage due to pulsing!
Press and hold the trigger (Fig. 23/3) until the loosing
process has been completed. Do not pulse (press and
release the trigger in quick succession).
ð
If loosening was successful, the next bolting process can
be started.
9.
If the bolting process does not start, ensure that the selected
torque level is not blocked
.
Fig. 23: Direction of rotation
1
Tightening in clockwise direction
2
Loosening in counterclockwise
direction
3
Trigger
Trigger
Loosening
54