Indication
56
H-METER
Press the ALARM RESET button to can-
cel the warning status. The unit will be in
the error half-reset/error reset condition.
Contact the dealer to replace the hard
disk.
Warning
The set time for the HOUR METER has
passed. (Refer to page 94.)
It may be reaching the end of the hard
disk’s lifetime.
W-ERROR
SMART
ALT-*
ERROR/WARNINGS
• The "error" status
When a fatal error (one that might cause the system to go down) has occurred, the ERROR indicator will blink red and the
error indication will be displayed on the monitor 2.
• The "warning" status
When an error (even though it has not caused the system trouble yet, but which may become a fatal error) has occurred,
the ERROR indicator will blink orange.
• When the buzzer sounding duration has passed from the error occurrence or the ALARM RESET button is pressed, the
error indication will disappear and the blinking ERROR indicator will light steadily. (Error half-reset)
If the error is eliminated, the ERROR indicator will go off when the ALARM RESET button is pressed while the ERROR indi-
cator is lit. (Error reset)
Status
Description
Solution
Error
Error
Warning
Recorded image has been altered.
Playback will be paused.
Failed to write data on the HDD.
The hard disk may be malfunctioning
and may not work correctly.
Press the ALARM RESET button to can-
cel the error status. The unit will be in
the error half-reset/error reset condition.
Press the PLAY/PAUSE button to resume
playback.
Press the ALARM RESET button to can-
cel the error status. The unit will be in
the error half-reset/error reset condition.
When the "W-ERROR" indication is dis-
played frequently, contact the dealer to
replace the hard disk drive.
Press the ALARM RESET button to can-
cel the warning status. The unit will be in
the error half-reset/error reset condition.
Contact the dealer to replace the hard
disk.
ERROR indicator on the
front panel
Blinks
Lights steadily
Off
Buzzer
Sounds (when it has been
set)
Stops
Stops
Error display area on the
main bar
Displays
Displays
Does not display
The error output (pin no.18)
of the ALARM/CONTROL
connector
Problem mail
Error log
Filed
–
–
Outputs
Transmitted (When it has
been set)
Does not output
–
Does not output
–
At an error occurrence
In the error half-reset
condition
In the error reset condition