67
Alarm Descriptions
■
Alarm Occurrence
When this unit accept an alarm input signal (terminal alarm, camera alarm, recorder alarm, serial alarm, or video loss), an
alarm event (tour sequence, etc.) is activated automatically. Each alarm input signal is associated with an alarm event setting.
(The setting activates the alarm input signal and alarm event.) Up to 1 024 alarm event settings are available. The alarm event
setting is performed in "Alarm" – "Alarm Event" of WJ-SX650 Series Administrator Console.
By performing the settings of "Alarm Event", the following events will be activated when this unit accepts an alarm input signal.
• Alarm event information will be displayed on the associated monitors (Refer to p. 13 Monitor Display Information.)
• Depending on the setting of "Display Mode", camera images will be displayed, or sequences will be activated on the asso-
ciated monitors. In this document, these actions are mentioned as the alarm mode, and pictures displayed during the
alarm mode is mentioned as alarm pictures.
• Depending on the setting of "Recording Source (LCN)", event recording will be activated. (Recording will follow the com-
mand alarm setting and event recording setting of recorder. Refer to the operating instructions of recorder for details.)
• Depending on the setting of "Alarm Output", alarm output signal will be supplied from the video output board, and external
alarm devices (buzzer, etc.) can be activated.
Notes:
• To activate alarm output signals from the ALARM OUT 1/2 port, perform settings of No.1 to 64. No.65 and greater are
assigned for serial commands.
• To activate alarm output signals as a serial command, serial command settings are required. The settings are per-
formed in "Communication" – "Serial Command" of WJ-SX650 Series Administrator Console.
• ALARM indicators of all system controllers blink.
• Up to 10 000 alarm records are saved chronologically. The latest 1 000 alarm records can be displayed as the alarm his-
tory on the monitor. (Refer to p. 70 Alarm History Display.) The Alarm History can be downloaded from the PC to the unit.
• Alarm information is notified to the PC in serial commands. The serial command setting is performed in "Communication" –
"Serial Command" of WJ-SX650 Series Administrator Console.
Terminal alarm setting
No.11(Dish)
No.10 (Pot)
No.1 (Entrance)
Sensor
system
Alarm Input 256
Matrix Switcher WJ-SX
650
650
Alarm input signal
from a sensor
ALARM
TIMER
HDD 2
ERROR
HDD 1
ALARM
SUSPEND
ALARM
RESET
OPERATE
MONITOR1
MONITOR2
1
5
9
13
2
6
10/0
14
3
7
11
15
4
8
12
16
SEQ
SHIFT
OSD
PAN/
TILT
STOP
PLAY
PAUSE
REC - REC STOP
ZOOM/
FOCUS
TEXT
COPY
DISK SELECT
EL-ZOOM
MARK
LOGOUT
IRIS
PRESET
/AUTO
A-B
REPEAT
GOTO
LAST
LISTED
SEARCH
BUSY
SETUP
/ESC
SET
REV
–
+
FWD
PULL
Digital Disk Recorder
WJ-HD
PAN/TILT
SLOW
Infrared sensor
Preset Position 1
(Zooming in No.1 (Entrance))
Monitor 5
Terminal Alarm
256
This unit
Camera 100
PC
Alarm Output 50
Recorder 1
Records the image
of Camera 100.
(Recording follows
the command alarm
setting and event
recording setting of
recorder.)
Notifies the
alarm event
occurrence.
No.
Display Mode
Spot
Monitor
Recording
Source (LCN)
Alarm Output
LCN
Preset
256
SPOT
100
1
5
100
50