43
Reference No.
11
12
13
14
1 to 8: Camera unit number
Note:
Camera unit number cannot be set for camera input channels accepting video input signals from
recorders. To activate RS-485 camera connections, set "OFF" for Control of these recorders in "System"
– "Recorder".
ON: Overlap
OFF: Not overlap
S: Less than 500 m {1 600 ft}
M: 500 m {1 600 ft} to 900 m {2 900 ft}
L: 900 m {2 900 ft} to 1 200 m {4 000 ft}
Note:
Refer to p. 27 for details on the cable length.
■
Tooltip Details
1
2
3
4
5
6
7
8
9
10
Explanation
1 to 8: Port No.
4800 bps, 9600 bps, 19200 bps, 38400 bps: Transmission speed
Character entry limit: 20 characters Available characters: Alphanumeric characters and symbols
1,2: Level
1 to 8: Video input board No.
Available parameters: Blank, 1 to 999
ON: Use
OFF: Not use
Note:
ON is not available for recorders when camera input channels are set for RS-485 cameras. To acti-
vate recorder connections, set "--" for the setting items of "RS485" and "Unit number" in "System" –
"VD2/DATA/Cable Comp." – "RS485 Camera".
Available parameters: Blank, 1 to 999
Note:
Select the camera numbers that has been set in "System" – "Logical Camera Number".
[DATA1] TMNL1, PSD: Port type
[DATA1] TMNL2: Port type
[DATA3] TMNL3, HDR1: Port type
[DATA4] TMNL4, HDR 2: Port type
[DATA5] TMNL 5: Port type
[DATA6] TMNL 6: Port type
[DATA7] TMNL7, HDR3: Port type
[DATA8] TMNL8, HDR4: Port type
4800 bps, 9600 bps, 19200 bps: Transmission speed
To change the transmission speed, conform the settings of this unit to that of connected devices.
[Input Board 1] 1 to 4: Port number
[Input Board 2] 5 to 8: Port number
[Input Board 3] 9 to 12: Port number
[Input Board 4] 13 to 16: Port number
[Input Board 5] 17 to 20: Port number
[Input Board 6] 21 to 24: Port number
[Input Board 7] 25 to 28: Port number
[Input Board 8] 29 to 32: Port number
Note:
Port numbers cannot be set for camera input channels accepting video input signals from recorders. To
activate RS-485 camera connections, set "OFF" for Control of these recorders in "System" – "Recorder".
Notes:
• Do not edit the setup data files by using text editors,
etc. You may become unable to open the setup data
files.
• To perform
q
,
w
, and
u
, this unit needs to be con-
nected to the PC with an RS-232C cable.
When you point the cursor on a button or pull-down menu,
a tooltip appears. Tool tips that have additional explana-
tions include reference numbers such as "
∗
1". Refer to the