84
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Product Description
4
4.8.3 Combo Tanks
The Combo Tanks are modern high-performance tanks, which were developed especially for the
requirements of the Aquarea heat pumps. They are a combination of a larger domestic hot water
tank located in the upper area of the tank and a smaller buffer tank located in the lower area. This
makes the Combo Tanks an ideal solution to supply a household with domestic hot water and
heating for radiators or underfloor heating. These compact models ensure very low standby losses
and quick assembly due to the pre-installed assembly groups such as 3-way valve or electric tank
heater (with safety thermostat and error signal contact)
The use of a Combo Tank helps implement multiple functions efficiently and easily, such as:
● Domestic hot water production
● Hydraulic disconnection of heat pump and heat consumer circuits
● Ensuring minimum required water volume in the heating system
● Buffer function for optimum operation of the Aquarea heat pumps
Panasonic offers one enamelled Combo Tank (PAW-TD20B8E3-2) and one stainless steel Combo
Tank (PAW-TD23B6E5).
i
Note
When installing a Combo Tank, observe the respective installation instructions enclosed with each
model. The installation instructions may contain important information about specific water quality
requirements and about additional accessories, which are needed for the installation of the tank in
the heating system and which must be provided by the client.
Enamelled Combo Tank: PAW-TD20B8E3-2
Components
B
16
2
1
3
4
5
18
17
A
2
1
3 4
5
6
7
8
9
10
11
15
14
16
17
18
12
13
A Internal view (seen from front side)
B Top view
1 Hot water outlet
2 Sacrificial anode
3 Fresh water inlet
4 Supply water outlet to heating circuit
5 Return water inlet from heating circuit (only seen in top
view)
6 Connection box
7 Connection terminal block (for 3-way valve, heating circuit
pump, electric tank heater and temperature sensor)
8 Electric tank heater (3 kW)
9 Overheating protection
10 Circulation pump (High efficiency pump)
11 Drain valve of the buffer tank
12 Air purge valve
13 Drain valve of the hot water tank
14 Heat insulation (Polyurethane, 50 mm)
15 3-way-valve
16 Cable gland (x 3)
17 Supply water inlet from the heat pump
18 Return water outlet to the heat pump
Содержание WH-ADC0309J3E5
Страница 2: ...Notes...
Страница 221: ...Notes...
Страница 222: ...1002 Aquarea air to water heat pumps Planning and installation manual 02 2022 Notes...
Страница 223: ...1003 Aquarea air to water heat pumps Planning and installation manual 02 2022 Notes...